The fsi bus got a dedicated probe function. Make use of that. This fixes
a runtime warning about the driver needing to be converted to the bus
probe method.
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
---
drivers/spi/spi-fsi.c | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)
diff --git a/drivers/spi/spi-fsi.c b/drivers/spi/spi-fsi.c
index f9c15b99dba5..07dc3d24f2c9 100644
--- a/drivers/spi/spi-fsi.c
+++ b/drivers/spi/spi-fsi.c
@@ -528,13 +528,13 @@ static size_t fsi_spi_max_transfer_size(struct spi_device *spi)
return SPI_FSI_MAX_RX_SIZE;
}
-static int fsi_spi_probe(struct device *dev)
+static int fsi_spi_probe(struct fsi_device *fsi)
{
int rc;
struct device_node *np;
int num_controllers_registered = 0;
struct fsi2spi *bridge;
- struct fsi_device *fsi = to_fsi_dev(dev);
+ struct device *dev = &fsi->dev;
rc = fsi_spi_check_mux(fsi, dev);
if (rc)
@@ -593,9 +593,9 @@ MODULE_DEVICE_TABLE(fsi, fsi_spi_ids);
static struct fsi_driver fsi_spi_driver = {
.id_table = fsi_spi_ids,
+ .probe = fsi_spi_probe,
.drv = {
.name = "spi-fsi",
- .probe = fsi_spi_probe,
},
};
module_fsi_driver(fsi_spi_driver);
--