[PATCH v2 2/8] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll

Varadarajan Narayanan posted 8 patches 2 years, 2 months ago
There is a newer version of this series
[PATCH v2 2/8] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll
Posted by Varadarajan Narayanan 2 years, 2 months ago
The set rate and determine rate operations are different between
Stromer and Stromer Plus PLLs. Hence, use stromer plus ops for
ipq_pll_stromer_plus.

Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332")
Signed-off-by: Kathiravan T <quic_kathirav@quicinc.com>
Signed-off-by: Varadarajan Narayanan <quic_varada@quicinc.com>
---
v2:	Add Fixes tag
---
 drivers/clk/qcom/apss-ipq-pll.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/clk/qcom/apss-ipq-pll.c b/drivers/clk/qcom/apss-ipq-pll.c
index e170331..18c4ffe 100644
--- a/drivers/clk/qcom/apss-ipq-pll.c
+++ b/drivers/clk/qcom/apss-ipq-pll.c
@@ -68,7 +68,7 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = {
 				.fw_name = "xo",
 			},
 			.num_parents = 1,
-			.ops = &clk_alpha_pll_stromer_ops,
+			.ops = &clk_alpha_pll_stromer_plus_ops,
 		},
 	},
 };
-- 
2.7.4