>> No. Intel doesn't reserve a single CLOS. It allows to assign RMIDs and CLOSids
>> for I/O monitoring and control. Different IDs can be assigned to different groups
>> of devices (the "grouping" is dependent on h/w routing to devices, not
>> assignable by the OS).
>
> How does this work with CDP on Intel? Can CDP be enabled for CPU agents while the
> "code" and "data" CLOSids be used for I/O control?
Reinette,
Good question. I'll have to check with h/w folks.
-Tony