drivers/thermal/gov_step_wise.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
From: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
The cooling logic description comment next to the get_target_state()
definition is slightly ambiguous in what it means by "lower cooling
state", so clarify that by replacing the ambuguous phrase with "the
minimum applicable cooling state".
No functional impact.
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
---
drivers/thermal/gov_step_wise.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)
--- a/drivers/thermal/gov_step_wise.c
+++ b/drivers/thermal/gov_step_wise.c
@@ -23,8 +23,8 @@
* b. if the trend is THERMAL_TREND_DROPPING, do nothing
* If the temperature is lower than a trip point,
* a. if the trend is THERMAL_TREND_RAISING, do nothing
- * b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
- * state for this trip point, if the cooling state already
+ * b. if the trend is THERMAL_TREND_DROPPING, use the minimum applicable
+ * cooling state for this trip point, or if the cooling state already
* equals lower limit, deactivate the thermal instance
*/
static unsigned long get_target_state(struct thermal_instance *instance,
On 8/25/25 14:28, Rafael J. Wysocki wrote: > From: Rafael J. Wysocki <rafael.j.wysocki@intel.com> > > The cooling logic description comment next to the get_target_state() > definition is slightly ambiguous in what it means by "lower cooling > state", so clarify that by replacing the ambuguous phrase with "the > minimum applicable cooling state". > > No functional impact. > > Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com> > --- > drivers/thermal/gov_step_wise.c | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) > > --- a/drivers/thermal/gov_step_wise.c > +++ b/drivers/thermal/gov_step_wise.c > @@ -23,8 +23,8 @@ > * b. if the trend is THERMAL_TREND_DROPPING, do nothing > * If the temperature is lower than a trip point, > * a. if the trend is THERMAL_TREND_RAISING, do nothing > - * b. if the trend is THERMAL_TREND_DROPPING, use lower cooling > - * state for this trip point, if the cooling state already > + * b. if the trend is THERMAL_TREND_DROPPING, use the minimum applicable > + * cooling state for this trip point, or if the cooling state already > * equals lower limit, deactivate the thermal instance > */ > static unsigned long get_target_state(struct thermal_instance *instance, > > > Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>