[PATCH 0/3] hwmon: arctic_fan_controller: PWM default, dual license, maintainer contact

Aureo Serrano de Souza posted 3 patches 2 weeks, 1 day ago
Documentation/hwmon/arctic_fan_controller.rst | 28 +++++++++----------
MAINTAINERS                                   |  2 +-
drivers/hwmon/arctic_fan_controller.c         | 22 +++++++++------
3 files changed, 27 insertions(+), 25 deletions(-)
[PATCH 0/3] hwmon: arctic_fan_controller: PWM default, dual license, maintainer contact
Posted by Aureo Serrano de Souza 2 weeks, 1 day ago
Follow-up to the ARCTIC Fan Controller driver merged for 7.2.

Patch 1 initializes the PWM cache to the MCU factory default of 40%
(sysfs 102) instead of 0, so a first single-channel write leaves the
other fans running at a safe speed. PWM is still not read from
periodic IN reports.

Patch 2 dual-licenses the driver and doc as GPL-2.0-or-later OR
BSD-2-Clause. Sole in-tree author; copyright ARCTIC.

Patch 3 points MAINTAINERS at arctic.it.hk@arctic.de.

This is a new series, not a v8 of the add-driver patches.


Aureo Serrano de Souza (3):
  hwmon: arctic_fan_controller: default PWM cache to MCU 40%
  hwmon: arctic_fan_controller: dual-license GPL-2.0-or-later OR
    BSD-2-Clause
  hwmon: arctic_fan_controller: use shared maintainer address

 Documentation/hwmon/arctic_fan_controller.rst | 28 +++++++++----------
 MAINTAINERS                                   |  2 +-
 drivers/hwmon/arctic_fan_controller.c         | 22 +++++++++------
 3 files changed, 27 insertions(+), 25 deletions(-)

-- 
2.43.0