[PATCH v2] iio: light: apds9306: fix default sampling frequency definition

Tsz Shan Chan posted 1 patch 3 weeks, 2 days ago
There is a newer version of this series
drivers/iio/light/apds9306.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
[PATCH v2] iio: light: apds9306: fix default sampling frequency definition
Posted by Tsz Shan Chan 3 weeks, 2 days ago
APDS9306_SAMP_FREQ_10HZ is defined as 0.

According to the datasheet (Broadcom AV02-4755EN,
https://docs.broadcom.com/doc/AV02-4755EN, page 11, ALS_MEAS_RATE),
bits[2:0] set the measurement rate:
- 000: 25ms  (40Hz)
- 001: 20ms  (20Hz)
- 010: 100ms (10Hz)

Change APDS9306_SAMP_FREQ_10HZ from 0 to 2 to write the correct value
for 10Hz.

Fixes: 620d1e6c7a3f ("iio: light: Add support for APDS9306 Light Sensor")
Signed-off-by: Tsz Shan Chan <tchan@jacques.com.au>
---
Changes in v2:
- Add datasheet link to commit message
- Remove blank line in the tag block
- Link to v1: https://lore.kernel.org/r/20260903-apds9306-v1-1-3f892aa4f156@jacques.com.au
---
 drivers/iio/light/apds9306.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/iio/light/apds9306.c b/drivers/iio/light/apds9306.c
index f681b02e4922..7dd41136734f 100644
--- a/drivers/iio/light/apds9306.c
+++ b/drivers/iio/light/apds9306.c
@@ -61,7 +61,7 @@
 #define APDS9306_NUM_REPEAT_RATES	7
 #define APDS9306_INT_SRC_CLEAR	0
 #define APDS9306_INT_SRC_ALS	1
-#define APDS9306_SAMP_FREQ_10HZ	0
+#define APDS9306_SAMP_FREQ_10HZ	2
 
 /**
  * struct part_id_gts_multiplier - Part no. and corresponding gts multiplier

---
base-commit: 940de590b839f71d6dc846160534bf202401b8b7
change-id: 20260903-apds9306-bedba7b74e59

Best regards,
-- 
Tsz Shan Chan <tchan@jacques.com.au>
Re: [PATCH v2] iio: light: apds9306: fix default sampling frequency definition
Posted by Andy Shevchenko 3 weeks, 2 days ago
On Thu, Sep 03, 2026 at 05:05:35PM +1000, Tsz Shan Chan wrote:
> APDS9306_SAMP_FREQ_10HZ is defined as 0.
> 
> According to the datasheet (Broadcom AV02-4755EN,
> https://docs.broadcom.com/doc/AV02-4755EN, page 11, ALS_MEAS_RATE),

Make it a tag

> bits[2:0] set the measurement rate:
> - 000: 25ms  (40Hz)
> - 001: 20ms  (20Hz)
> - 010: 100ms (10Hz)
> 
> Change APDS9306_SAMP_FREQ_10HZ from 0 to 2 to write the correct value
> for 10Hz.

Datasheet: $URL

> Fixes: 620d1e6c7a3f ("iio: light: Add support for APDS9306 Light Sensor")
> Signed-off-by: Tsz Shan Chan <tchan@jacques.com.au>

With that being addressed,
Reviewed-by: Andy Shevchenko <andriy.shevchenko@intel.com>

-- 
With Best Regards,
Andy Shevchenko
Re: [PATCH v2] iio: light: apds9306: fix default sampling frequency definition
Posted by Tsz Shan Chan 3 weeks, 1 day ago
On Thu, Sep 03, 2026 at 10:48:27AM +0300, Andy Shevchenko wrote:
> On Thu, Sep 03, 2026 at 05:05:35PM +1000, Tsz Shan Chan wrote:
> > APDS9306_SAMP_FREQ_10HZ is defined as 0.
> > 
> > According to the datasheet (Broadcom AV02-4755EN,
> > https://docs.broadcom.com/doc/AV02-4755EN, page 11, ALS_MEAS_RATE),
> 
> Make it a tag
> 
> > bits[2:0] set the measurement rate:
> > - 000: 25ms  (40Hz)
> > - 001: 20ms  (20Hz)
> > - 010: 100ms (10Hz)
> > 
> > Change APDS9306_SAMP_FREQ_10HZ from 0 to 2 to write the correct value
> > for 10Hz.
> 
> Datasheet: $URL
> 
> > Fixes: 620d1e6c7a3f ("iio: light: Add support for APDS9306 Light Sensor")
> > Signed-off-by: Tsz Shan Chan <tchan@jacques.com.au>
> 
> With that being addressed,
> Reviewed-by: Andy Shevchenko <andriy.shevchenko@intel.com>

Will fix it in v3. Thanks