[RFC PATCH v2 0/2] hwmon: emc2305: Support configurable fan PWM at shutdown

florin.leotescu@oss.nxp.com posted 2 patches 3 weeks, 5 days ago
There is a newer version of this series
.../bindings/hwmon/microchip,emc2305.yaml     |  8 +++++
drivers/hwmon/emc2305.c                       | 35 +++++++++++++++++++
2 files changed, 43 insertions(+)
[RFC PATCH v2 0/2] hwmon: emc2305: Support configurable fan PWM at shutdown
Posted by florin.leotescu@oss.nxp.com 3 weeks, 5 days ago
From: Florin Leotescu <florin.leotescu@nxp.com>

This series adds support for configuring the fan PWM duty cycle applied
during system shutdown for the EMC2305 fan controller.

Some platforms require fans to transition to a predefined safe state
during shutdown or reboot handoff until firmware or the next boot stage
reconfigures the controller.

The new optional Device Tree property "fan-shutdown-percent" allows the
shutdown PWM duty cycle to be configured per fan output.

Changes in v2:
- Address feedback from Guenter Roeck
- Make shutdown behavior configurable via Device Tree
- Add optional fan-shutdown-percent property
- Apply shutdown PWM only for channels defining the property

Florin Leotescu (2):
  dt-bindings: hwmon: emc2305: Add fan-shutdown-percent property
  hwmon: emc2305: Support configurable fan PWM at shutdown

 .../bindings/hwmon/microchip,emc2305.yaml     |  8 +++++
 drivers/hwmon/emc2305.c                       | 35 +++++++++++++++++++
 2 files changed, 43 insertions(+)

-- 
2.34.1