[PATCH] iio: accel: iis328dq: fix gain values

Markus Koeniger via B4 Relay posted 1 patch 1 month, 2 weeks ago
There is a newer version of this series
drivers/iio/accel/st_accel_core.c | 72 ++++++++++++++++++++++++++++++++++++++-
1 file changed, 71 insertions(+), 1 deletion(-)
[PATCH] iio: accel: iis328dq: fix gain values
Posted by Markus Koeniger via B4 Relay 1 month, 2 weeks ago
From: Markus Koeniger <markus.koeniger@liebherr.com>

The sensors IIS328DQ and H3LIS331DL share one configuration but
H3LIS331DL has different gain parameters, configs therefore
need to be split up.
The gain parameters for the IIS328DQ are 0.98, 1.95 and 3.91,
depending on the selected measurement range.

See sensor manuals, chapter 2.1 "mechanical characteristics",
parameter "Sensitivity":
IIS328DQ https://www.st.com/resource/en/datasheet/iis328dq.pdf
H3LIS331DL https://www.st.com/resource/en/datasheet/h3lis331dl.pdf

Fixes: 46e33707fe95 ("iio: accel: add support for IIS328DQ variant")
Reviewed-by: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
Signed-off-by: Markus Koeniger <markus.koeniger@liebherr.com>
---
Fix gain value of IIS328DQ accelerometer. The typical gain parameters for 
the IIS328DQ are 0.98, 1.95 and 3.91, depending on the selected 
measurement range. The configuration for IIS328DQ and H3LIS331DL needs 
to be split up as H3LIS331DL has different gains of 49, 98 and 195. 
---
 drivers/iio/accel/st_accel_core.c | 72 ++++++++++++++++++++++++++++++++++++++-
 1 file changed, 71 insertions(+), 1 deletion(-)

diff --git a/drivers/iio/accel/st_accel_core.c b/drivers/iio/accel/st_accel_core.c
index 99cb661fabb2..afd97216d8ae 100644
--- a/drivers/iio/accel/st_accel_core.c
+++ b/drivers/iio/accel/st_accel_core.c
@@ -517,7 +517,6 @@ static const struct st_sensor_settings st_accel_sensors_settings[] = {
 		.wai_addr = ST_SENSORS_DEFAULT_WAI_ADDRESS,
 		.sensors_supported = {
 			[0] = H3LIS331DL_ACCEL_DEV_NAME,
-			[1] = IIS328DQ_ACCEL_DEV_NAME,
 		},
 		.ch = (struct iio_chan_spec *)st_accel_12bit_channels,
 		.odr = {
@@ -584,6 +583,77 @@ static const struct st_sensor_settings st_accel_sensors_settings[] = {
 		.multi_read_bit = true,
 		.bootime = 2,
 	},
+	{
+		.wai = 0x32,
+		.wai_addr = ST_SENSORS_DEFAULT_WAI_ADDRESS,
+		.sensors_supported = {
+			[0] = IIS328DQ_ACCEL_DEV_NAME,
+		},
+		.ch = (struct iio_chan_spec *)st_accel_12bit_channels,
+		.odr = {
+			.addr = 0x20,
+			.mask = 0x18,
+			.odr_avl = {
+				{ .hz = 50, .value = 0x00, },
+				{ .hz = 100, .value = 0x01, },
+				{ .hz = 400, .value = 0x02, },
+				{ .hz = 1000, .value = 0x03, },
+			},
+		},
+		.pw = {
+			.addr = 0x20,
+			.mask = 0x20,
+			.value_on = ST_SENSORS_DEFAULT_POWER_ON_VALUE,
+			.value_off = ST_SENSORS_DEFAULT_POWER_OFF_VALUE,
+		},
+		.enable_axis = {
+			.addr = ST_SENSORS_DEFAULT_AXIS_ADDR,
+			.mask = ST_SENSORS_DEFAULT_AXIS_MASK,
+		},
+		.fs = {
+			.addr = 0x23,
+			.mask = 0x30,
+			.fs_avl = {
+				[0] = {
+					.num = ST_ACCEL_FS_AVL_100G,
+					.value = 0x00,
+					.gain = IIO_G_TO_M_S_2(980),
+				},
+				[1] = {
+					.num = ST_ACCEL_FS_AVL_200G,
+					.value = 0x01,
+					.gain = IIO_G_TO_M_S_2(1950),
+				},
+				[2] = {
+					.num = ST_ACCEL_FS_AVL_400G,
+					.value = 0x03,
+					.gain = IIO_G_TO_M_S_2(3910),
+				},
+			},
+		},
+		.bdu = {
+			.addr = 0x23,
+			.mask = 0x80,
+		},
+		.drdy_irq = {
+			.int1 = {
+				.addr = 0x22,
+				.mask = 0x02,
+			},
+			.int2 = {
+				.addr = 0x22,
+				.mask = 0x10,
+			},
+			.addr_ihl = 0x22,
+			.mask_ihl = 0x80,
+		},
+		.sim = {
+			.addr = 0x23,
+			.value = BIT(0),
+		},
+		.multi_read_bit = true,
+		.bootime = 2,
+	},
 	{
 		/* No WAI register present */
 		.sensors_supported = {

---
base-commit: 19272b37aa4f83ca52bdf9c16d5d81bdd1354494
change-id: 20251222-iio-accel-iis328dq-fix-gains-c281f9961b22

Best regards,
-- 
Markus Koeniger <markus.koeniger@liebherr.com>
Re: [PATCH] iio: accel: iis328dq: fix gain values
Posted by Andy Shevchenko 1 month, 2 weeks ago
On Mon, Dec 22, 2025 at 03:50:04PM +0100, Markus Koeniger via B4 Relay wrote:
> From: Markus Koeniger <markus.koeniger@liebherr.com>
> 
> The sensors IIS328DQ and H3LIS331DL share one configuration but
> H3LIS331DL has different gain parameters, configs therefore
> need to be split up.
> The gain parameters for the IIS328DQ are 0.98, 1.95 and 3.91,
> depending on the selected measurement range.

> See sensor manuals, chapter 2.1 "mechanical characteristics",
> parameter "Sensitivity":
> IIS328DQ https://www.st.com/resource/en/datasheet/iis328dq.pdf
> H3LIS331DL https://www.st.com/resource/en/datasheet/h3lis331dl.pdf

You can make them as Datasheet tags:

  ...
  See sensor manuals, chapter 2.1 "mechanical characteristics",
  parameter "Sensitivity" in the datasheet.

  Datasheet: https://www.st.com/resource/en/datasheet/iis328dq.pdf
  Datasheet: https://www.st.com/resource/en/datasheet/h3lis331dl.pdf
  Fixes: ...
  ...

> Fixes: 46e33707fe95 ("iio: accel: add support for IIS328DQ variant")
> Reviewed-by: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
> Signed-off-by: Markus Koeniger <markus.koeniger@liebherr.com>

-- 
With Best Regards,
Andy Shevchenko