[PATCH net-next v7 20/26] selftests/vsock: avoid false-positives when checking dmesg

Bobby Eshleman posted 26 patches 3 months, 2 weeks ago
There is a newer version of this series
[PATCH net-next v7 20/26] selftests/vsock: avoid false-positives when checking dmesg
Posted by Bobby Eshleman 3 months, 2 weeks ago
From: Bobby Eshleman <bobbyeshleman@meta.com>

Sometimes VMs will have some intermittent dmesg warnings that are
unrelated to vsock. Change the dmesg parsing to filter on strings
containing 'vsock' to avoid false positive failures that are unrelated
to vsock. The downside is that it is possible for some vsock related
warnings to not contain the substring 'vsock', so those will be missed.

Fixes: a4a65c6fe08b ("selftests/vsock: add initial vmtest.sh for vsock")
Signed-off-by: Bobby Eshleman <bobbyeshleman@meta.com>
---
 tools/testing/selftests/vsock/vmtest.sh | 8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)

diff --git a/tools/testing/selftests/vsock/vmtest.sh b/tools/testing/selftests/vsock/vmtest.sh
index 9afe8177167e..b129976e27fc 100755
--- a/tools/testing/selftests/vsock/vmtest.sh
+++ b/tools/testing/selftests/vsock/vmtest.sh
@@ -591,9 +591,9 @@ run_shared_vm_test() {
 	local rc
 
 	host_oops_cnt_before=$(dmesg | grep -c -i 'Oops')
-	host_warn_cnt_before=$(dmesg --level=warn | wc -l)
+	host_warn_cnt_before=$(dmesg --level=warn | grep -c -i 'vsock')
 	vm_oops_cnt_before=$(vm_ssh "init_ns" -- dmesg | grep -c -i 'Oops')
-	vm_warn_cnt_before=$(vm_ssh "init_ns" -- dmesg --level=warn | wc -l)
+	vm_warn_cnt_before=$(vm_ssh "init_ns" -- dmesg --level=warn | grep -c -i 'vsock')
 
 	name=$(echo "${1}" | awk '{ print $1 }')
 	eval test_"${name}"
@@ -605,7 +605,7 @@ run_shared_vm_test() {
 		rc=$KSFT_FAIL
 	fi
 
-	host_warn_cnt_after=$(dmesg --level=warn | wc -l)
+	host_warn_cnt_after=$(dmesg --level=warn | grep -c -i vsock)
 	if [[ ${host_warn_cnt_after} -gt ${host_warn_cnt_before} ]]; then
 		echo "FAIL: kernel warning detected on host" | log_host
 		rc=$KSFT_FAIL
@@ -617,7 +617,7 @@ run_shared_vm_test() {
 		rc=$KSFT_FAIL
 	fi
 
-	vm_warn_cnt_after=$(vm_ssh "init_ns" -- dmesg --level=warn | wc -l)
+	vm_warn_cnt_after=$(vm_ssh "init_ns" -- dmesg --level=warn | grep -c -i vsock)
 	if [[ ${vm_warn_cnt_after} -gt ${vm_warn_cnt_before} ]]; then
 		echo "FAIL: kernel warning detected on vm" | log_host
 		rc=$KSFT_FAIL

-- 
2.47.3