drivers/iio/humidity/hdc3020.c | 73 +++++++++++++++++++++++++----------------- 1 file changed, 43 insertions(+), 30 deletions(-)
Fix units to milli degree celsius and milli percent for temperature
respectively relative humidity measurements and thresholds.
Signed-off-by: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
---
Changes in v4:
- Add explicit formula into comments of hdc3020_thresh_get_temp and
hdc3020_thresh_get_hum
- Add explicit division by 5 into calculations in hdc3020_thresh_get_temp
and hdc3020_thresh_get_hum
- Link to v3: https://lore.kernel.org/r/20251013-hdc3020-units-fix-v3-0-b21fab32b882@liebherr.com
Changes in v3:
- Fix verbose comment for define HDC3020_THRESH_FRACTION (Javier)
- Embed prescale into define HDC3020_THRESH_FRACTION to make the division
by 5 calculation in threshold calculations explicit. (Andy)
- Add resulting units into comments again in hdc3020_thresh_get_temp and
hdc3020_thresh_get_hum (Andy)
- Link to v2: https://lore.kernel.org/r/20250901-hdc3020-units-fix-v2-0-082038a15917@liebherr.com
Changes in v2:
- Added explanation what is wrong at the moment into commit msg
- Added define HDC3020_THRESH_FRACTION and comment at the beginning of the
code.
- Use MILLI for instead of hardcoded 1000.
- Link to v1: https://lore.kernel.org/r/20250821-hdc3020-units-fix-v1-0-6ab0bc353c5e@liebherr.com
---
Dimitri Fedrau (2):
iio: humditiy: hdc3020: fix units for temperature and humidity measurement
iio: humditiy: hdc3020: fix units for thresholds and hysteresis
drivers/iio/humidity/hdc3020.c | 73 +++++++++++++++++++++++++-----------------
1 file changed, 43 insertions(+), 30 deletions(-)
---
base-commit: 875e7d357a7f2e77a7f3fc4759d0aa0872c33027
change-id: 20250820-hdc3020-units-fix-91edbb8ccd07
Best regards,
--
Dimitri Fedrau <dimitri.fedrau@liebherr.com>
On Thu, 16 Oct 2025 07:20:37 +0200 Dimitri Fedrau via B4 Relay <devnull+dimitri.fedrau.liebherr.com@kernel.org> wrote: > Fix units to milli degree celsius and milli percent for temperature > respectively relative humidity measurements and thresholds. > > Signed-off-by: Dimitri Fedrau <dimitri.fedrau@liebherr.com> Hi Dimitri, I think this covers the last bits of feedback so I'll queue it up in the fixes-togreg branch of iio.git. I'll probably not send a pull request for that for a few more days though so there is still time for additional feedback. Also marked for stable. Thanks Jonathan > --- > Changes in v4: > - Add explicit formula into comments of hdc3020_thresh_get_temp and > hdc3020_thresh_get_hum > - Add explicit division by 5 into calculations in hdc3020_thresh_get_temp > and hdc3020_thresh_get_hum > - Link to v3: https://lore.kernel.org/r/20251013-hdc3020-units-fix-v3-0-b21fab32b882@liebherr.com > > Changes in v3: > - Fix verbose comment for define HDC3020_THRESH_FRACTION (Javier) > - Embed prescale into define HDC3020_THRESH_FRACTION to make the division > by 5 calculation in threshold calculations explicit. (Andy) > - Add resulting units into comments again in hdc3020_thresh_get_temp and > hdc3020_thresh_get_hum (Andy) > - Link to v2: https://lore.kernel.org/r/20250901-hdc3020-units-fix-v2-0-082038a15917@liebherr.com > > Changes in v2: > - Added explanation what is wrong at the moment into commit msg > - Added define HDC3020_THRESH_FRACTION and comment at the beginning of the > code. > - Use MILLI for instead of hardcoded 1000. > - Link to v1: https://lore.kernel.org/r/20250821-hdc3020-units-fix-v1-0-6ab0bc353c5e@liebherr.com > > --- > Dimitri Fedrau (2): > iio: humditiy: hdc3020: fix units for temperature and humidity measurement > iio: humditiy: hdc3020: fix units for thresholds and hysteresis > > drivers/iio/humidity/hdc3020.c | 73 +++++++++++++++++++++++++----------------- > 1 file changed, 43 insertions(+), 30 deletions(-) > --- > base-commit: 875e7d357a7f2e77a7f3fc4759d0aa0872c33027 > change-id: 20250820-hdc3020-units-fix-91edbb8ccd07 > > Best regards,