[PATCH 0/2] iio: humditiy: hdc3020: fix units

Dimitri Fedrau via B4 Relay posted 2 patches 1 month, 1 week ago
There is a newer version of this series
drivers/iio/humidity/hdc3020.c | 46 +++++++++++++++++++++---------------------
1 file changed, 23 insertions(+), 23 deletions(-)
[PATCH 0/2] iio: humditiy: hdc3020: fix units
Posted by Dimitri Fedrau via B4 Relay 1 month, 1 week ago
Fix units to milli degree celsius and milli percent for temperature
respectively relative humidity measurements and thresholds.

Signed-off-by: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
---
Dimitri Fedrau (2):
      iio: humditiy: hdc3020: fix units for temperature and humidity measurement
      iio: humditiy: hdc3020: fix units for thresholds and hysteresis

 drivers/iio/humidity/hdc3020.c | 46 +++++++++++++++++++++---------------------
 1 file changed, 23 insertions(+), 23 deletions(-)
---
base-commit: 43c0f6456f801181a80b73d95def0e0fd134e1cc
change-id: 20250820-hdc3020-units-fix-91edbb8ccd07