[PATCH net] net: dsa: b53: prevent standalone from trying to forward to other ports

Jonas Gorski posted 1 patch 7 months, 1 week ago
drivers/net/dsa/b53/b53_common.c | 33 ++++++++++++++++++++++++++++++++
drivers/net/dsa/b53/b53_regs.h   | 14 ++++++++++++++
2 files changed, 47 insertions(+)
[PATCH net] net: dsa: b53: prevent standalone from trying to forward to other ports
Posted by Jonas Gorski 7 months, 1 week ago
When bridged ports and standalone ports share a VLAN, e.g. via VLAN
uppers, or untagged traffic with a vlan unaware bridge, the ASIC will
still try to forward traffic to known FDB entries on standalone ports.
But since the port VLAN masks prevent forwarding to bridged ports, this
traffic will be dropped.

This e.g. can be observed in the bridge_vlan_unaware ping tests, where
this breaks pinging with learning on.

Work around this by enabling the simplified EAP mode on switches
supporting it for standalone ports, which causes the ASIC to redirect
traffic of unknown source MAC addresses to the CPU port.

Since standalone ports do not learn, there are no known source MAC
addresses, so effectively this redirects all incoming traffic to the CPU
port.

Fixes: ff39c2d68679 ("net: dsa: b53: Add bridge support")
Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
---
 drivers/net/dsa/b53/b53_common.c | 33 ++++++++++++++++++++++++++++++++
 drivers/net/dsa/b53/b53_regs.h   | 14 ++++++++++++++
 2 files changed, 47 insertions(+)

diff --git a/drivers/net/dsa/b53/b53_common.c b/drivers/net/dsa/b53/b53_common.c
index 9eb39cfa5fb2..7216eb8f9493 100644
--- a/drivers/net/dsa/b53/b53_common.c
+++ b/drivers/net/dsa/b53/b53_common.c
@@ -326,6 +326,26 @@ static void b53_get_vlan_entry(struct b53_device *dev, u16 vid,
 	}
 }
 
+static void b53_set_eap_mode(struct b53_device *dev, int port, int mode)
+{
+	u64 eap_conf;
+
+	if (is5325(dev) || is5365(dev) || dev->chip_id == BCM5389_DEVICE_ID)
+		return;
+
+	b53_read64(dev, B53_EAP_PAGE, B53_PORT_EAP_CONF(port), &eap_conf);
+
+	if (is63xx(dev)) {
+		eap_conf &= ~EAP_MODE_MASK_63XX;
+		eap_conf |= (u64)mode << EAP_MODE_SHIFT_63XX;
+	} else {
+		eap_conf &= ~EAP_MODE_MASK;
+		eap_conf |= (u64)mode << EAP_MODE_SHIFT;
+	}
+
+	b53_write64(dev, B53_EAP_PAGE, B53_PORT_EAP_CONF(port), eap_conf);
+}
+
 static void b53_set_forwarding(struct b53_device *dev, int enable)
 {
 	u8 mgmt;
@@ -586,6 +606,13 @@ int b53_setup_port(struct dsa_switch *ds, int port)
 	b53_port_set_mcast_flood(dev, port, true);
 	b53_port_set_learning(dev, port, false);
 
+	/* Force all traffic to go to the CPU port to prevent the ASIC from
+	 * trying to forward to bridged ports on matching FDB entries, then
+	 * dropping frames because it isn't allowed to forward there.
+	 */
+	if (dsa_is_user_port(ds, port))
+		b53_set_eap_mode(dev, port, EAP_MODE_SIMPLIFIED);
+
 	return 0;
 }
 EXPORT_SYMBOL(b53_setup_port);
@@ -2042,6 +2069,9 @@ int b53_br_join(struct dsa_switch *ds, int port, struct dsa_bridge bridge,
 		pvlan |= BIT(i);
 	}
 
+	/* Disable redirection of unknown SA to the CPU port */
+	b53_set_eap_mode(dev, port, EAP_MODE_BASIC);
+
 	/* Configure the local port VLAN control membership to include
 	 * remote ports and update the local port bitmask
 	 */
@@ -2077,6 +2107,9 @@ void b53_br_leave(struct dsa_switch *ds, int port, struct dsa_bridge bridge)
 			pvlan &= ~BIT(i);
 	}
 
+	/* Enable redirection of unknown SA to the CPU port */
+	b53_set_eap_mode(dev, port, EAP_MODE_SIMPLIFIED);
+
 	b53_write16(dev, B53_PVLAN_PAGE, B53_PVLAN_PORT_MASK(port), pvlan);
 	dev->ports[port].vlan_ctl_mask = pvlan;
 
diff --git a/drivers/net/dsa/b53/b53_regs.h b/drivers/net/dsa/b53/b53_regs.h
index bfbcb66bef66..5f7a0e5c5709 100644
--- a/drivers/net/dsa/b53/b53_regs.h
+++ b/drivers/net/dsa/b53/b53_regs.h
@@ -50,6 +50,9 @@
 /* Jumbo Frame Registers */
 #define B53_JUMBO_PAGE			0x40
 
+/* EAP Registers */
+#define B53_EAP_PAGE			0x42
+
 /* EEE Control Registers Page */
 #define B53_EEE_PAGE			0x92
 
@@ -480,6 +483,17 @@
 #define   JMS_MIN_SIZE			1518
 #define   JMS_MAX_SIZE			9724
 
+/*************************************************************************
+ * EAP Page Registers
+ *************************************************************************/
+#define B53_PORT_EAP_CONF(i)		(0x20 + 8 * (i))
+#define  EAP_MODE_SHIFT			51
+#define  EAP_MODE_SHIFT_63XX		50
+#define  EAP_MODE_MASK			(0x3ull << EAP_MODE_SHIFT)
+#define  EAP_MODE_MASK_63XX		(0x3ull << EAP_MODE_SHIFT_63XX)
+#define  EAP_MODE_BASIC			0
+#define  EAP_MODE_SIMPLIFIED		3
+
 /*************************************************************************
  * EEE Configuration Page Registers
  *************************************************************************/
-- 
2.43.0
Re: [PATCH net] net: dsa: b53: prevent standalone from trying to forward to other ports
Posted by Vladimir Oltean 7 months ago
On Thu, May 08, 2025 at 11:14:24AM +0200, Jonas Gorski wrote:
> When bridged ports and standalone ports share a VLAN, e.g. via VLAN
> uppers, or untagged traffic with a vlan unaware bridge, the ASIC will
> still try to forward traffic to known FDB entries on standalone ports.
> But since the port VLAN masks prevent forwarding to bridged ports, this
> traffic will be dropped.
> 
> This e.g. can be observed in the bridge_vlan_unaware ping tests, where
> this breaks pinging with learning on.
> 
> Work around this by enabling the simplified EAP mode on switches
> supporting it for standalone ports, which causes the ASIC to redirect
> traffic of unknown source MAC addresses to the CPU port.
> 
> Since standalone ports do not learn, there are no known source MAC
> addresses, so effectively this redirects all incoming traffic to the CPU
> port.
> 
> Fixes: ff39c2d68679 ("net: dsa: b53: Add bridge support")
> Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>
> ---

Reviewed-by: Vladimir Oltean <olteanv@gmail.com>
Re: [PATCH net] net: dsa: b53: prevent standalone from trying to forward to other ports
Posted by Florian Fainelli 7 months ago

On 5/8/2025 11:14 AM, Jonas Gorski wrote:
> When bridged ports and standalone ports share a VLAN, e.g. via VLAN
> uppers, or untagged traffic with a vlan unaware bridge, the ASIC will
> still try to forward traffic to known FDB entries on standalone ports.
> But since the port VLAN masks prevent forwarding to bridged ports, this
> traffic will be dropped.
> 
> This e.g. can be observed in the bridge_vlan_unaware ping tests, where
> this breaks pinging with learning on.
> 
> Work around this by enabling the simplified EAP mode on switches
> supporting it for standalone ports, which causes the ASIC to redirect
> traffic of unknown source MAC addresses to the CPU port.
> 
> Since standalone ports do not learn, there are no known source MAC
> addresses, so effectively this redirects all incoming traffic to the CPU
> port.
> 
> Fixes: ff39c2d68679 ("net: dsa: b53: Add bridge support")
> Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>

Reviewed-by: Florian Fainelli <florian.fainelli@broadcom.com>
-- 
Florian
Re: [PATCH net] net: dsa: b53: prevent standalone from trying to forward to other ports
Posted by Paolo Abeni 7 months ago
On 5/8/25 11:14 AM, Jonas Gorski wrote:
> When bridged ports and standalone ports share a VLAN, e.g. via VLAN
> uppers, or untagged traffic with a vlan unaware bridge, the ASIC will
> still try to forward traffic to known FDB entries on standalone ports.
> But since the port VLAN masks prevent forwarding to bridged ports, this
> traffic will be dropped.
> 
> This e.g. can be observed in the bridge_vlan_unaware ping tests, where
> this breaks pinging with learning on.
> 
> Work around this by enabling the simplified EAP mode on switches
> supporting it for standalone ports, which causes the ASIC to redirect
> traffic of unknown source MAC addresses to the CPU port.
> 
> Since standalone ports do not learn, there are no known source MAC
> addresses, so effectively this redirects all incoming traffic to the CPU
> port.
> 
> Fixes: ff39c2d68679 ("net: dsa: b53: Add bridge support")
> Signed-off-by: Jonas Gorski <jonas.gorski@gmail.com>

@Florian, could you please have a look at this one, too?