For historical reasons syscon-reboot has used an 'offset' property. As a
child on a MMIO bus having a 'reg' property is more appropriate. Accept
'reg' as an alternative to 'offset'.
Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
---
Notes:
Changes in v6:
- Add r-by from Krzysztof
Changes in v5:
- New, making the driver accept the updated binding
drivers/power/reset/syscon-reboot.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/drivers/power/reset/syscon-reboot.c b/drivers/power/reset/syscon-reboot.c
index 4d622c19bc48..d623d77e657e 100644
--- a/drivers/power/reset/syscon-reboot.c
+++ b/drivers/power/reset/syscon-reboot.c
@@ -61,7 +61,8 @@ static int syscon_reboot_probe(struct platform_device *pdev)
priority = 192;
if (of_property_read_u32(pdev->dev.of_node, "offset", &ctx->offset))
- return -EINVAL;
+ if (of_property_read_u32(pdev->dev.of_node, "reg", &ctx->offset))
+ return -EINVAL;
value_err = of_property_read_u32(pdev->dev.of_node, "value", &ctx->value);
mask_err = of_property_read_u32(pdev->dev.of_node, "mask", &ctx->mask);
--
2.47.0