The BM(P/E)28x devices have an option for soft reset which is also
recommended by the Bosch Sensortech BME2 Sensor API to be used before the
initial configuration of the device.
Link: https://github.com/boschsensortec/BME280_SensorAPI/blob/bme280_v3.5.1/bme280.c#L429
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
---
drivers/iio/pressure/bmp280-core.c | 26 ++++++++++++++++++++++++++
drivers/iio/pressure/bmp280.h | 3 +++
2 files changed, 29 insertions(+)
diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index c23515048081..e01c9369bd67 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -965,6 +965,30 @@ static const unsigned long bme280_avail_scan_masks[] = {
0
};
+static int bmp280_preinit(struct bmp280_data *data)
+{
+ unsigned int reg;
+ int ret;
+
+ ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD);
+ if (ret)
+ return dev_err_probe(data->dev, ret,
+ "Failed to reset device.\n");
+
+ usleep_range(data->start_up_time, data->start_up_time + 500);
+
+ ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®);
+ if (ret)
+ return dev_err_probe(data->dev, ret,
+ "Failed to read status register.\n");
+
+ if (reg & BMP280_REG_STATUS_IM_UPDATE)
+ return dev_err_probe(data->dev, ret,
+ "Failed to copy NVM contents.\n");
+
+ return 0;
+}
+
static int bmp280_chip_config(struct bmp280_data *data)
{
u8 osrs = FIELD_PREP(BMP280_OSRS_TEMP_MASK, data->oversampling_temp + 1) |
@@ -1082,6 +1106,7 @@ const struct bmp280_chip_info bmp280_chip_info = {
.read_temp = bmp280_read_temp,
.read_press = bmp280_read_press,
.read_calib = bmp280_read_calib,
+ .preinit = bmp280_preinit,
.trigger_handler = bmp280_trigger_handler,
};
@@ -1202,6 +1227,7 @@ const struct bmp280_chip_info bme280_chip_info = {
.read_press = bmp280_read_press,
.read_humid = bme280_read_humid,
.read_calib = bme280_read_calib,
+ .preinit = bmp280_preinit,
.trigger_handler = bme280_trigger_handler,
};
diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h
index 4e675401d61b..73516878d020 100644
--- a/drivers/iio/pressure/bmp280.h
+++ b/drivers/iio/pressure/bmp280.h
@@ -205,6 +205,9 @@
#define BMP280_REG_CONFIG 0xF5
#define BMP280_REG_CTRL_MEAS 0xF4
#define BMP280_REG_STATUS 0xF3
+#define BMP280_REG_STATUS_IM_UPDATE BIT(0)
+#define BMP280_REG_RESET 0xE0
+#define BMP280_RST_SOFT_CMD 0xB6
#define BMP280_REG_COMP_TEMP_START 0x88
#define BMP280_COMP_TEMP_REG_COUNT 6
--
2.25.1
Le 23/08/2024 à 20:17, Vasileios Amoiridis a écrit :
> The BM(P/E)28x devices have an option for soft reset which is also
> recommended by the Bosch Sensortech BME2 Sensor API to be used before the
> initial configuration of the device.
>
> Link: https://github.com/boschsensortec/BME280_SensorAPI/blob/bme280_v3.5.1/bme280.c#L429
> Signed-off-by: Vasileios Amoiridis <vassilisamir-Re5JQEeQqe8AvxtiuMwx3w@public.gmane.org>
> ---
> drivers/iio/pressure/bmp280-core.c | 26 ++++++++++++++++++++++++++
> drivers/iio/pressure/bmp280.h | 3 +++
> 2 files changed, 29 insertions(+)
>
> diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
> index c23515048081..e01c9369bd67 100644
> --- a/drivers/iio/pressure/bmp280-core.c
> +++ b/drivers/iio/pressure/bmp280-core.c
> @@ -965,6 +965,30 @@ static const unsigned long bme280_avail_scan_masks[] = {
> 0
> };
>
> +static int bmp280_preinit(struct bmp280_data *data)
> +{
> + unsigned int reg;
> + int ret;
> +
> + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD);
> + if (ret)
> + return dev_err_probe(data->dev, ret,
> + "Failed to reset device.\n");
> +
> + usleep_range(data->start_up_time, data->start_up_time + 500);
> +
> + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®);
> + if (ret)
> + return dev_err_probe(data->dev, ret,
> + "Failed to read status register.\n");
> +
> + if (reg & BMP280_REG_STATUS_IM_UPDATE)
> + return dev_err_probe(data->dev, ret,
> + "Failed to copy NVM contents.\n");
ret is 0 at this point.
Should a -E<something> be used instead?
CJ
> +
> + return 0;
> +}
> +
> static int bmp280_chip_config(struct bmp280_data *data)
> {
> u8 osrs = FIELD_PREP(BMP280_OSRS_TEMP_MASK, data->oversampling_temp + 1) |
> @@ -1082,6 +1106,7 @@ const struct bmp280_chip_info bmp280_chip_info = {
> .read_temp = bmp280_read_temp,
> .read_press = bmp280_read_press,
> .read_calib = bmp280_read_calib,
> + .preinit = bmp280_preinit,
>
> .trigger_handler = bmp280_trigger_handler,
> };
> @@ -1202,6 +1227,7 @@ const struct bmp280_chip_info bme280_chip_info = {
> .read_press = bmp280_read_press,
> .read_humid = bme280_read_humid,
> .read_calib = bme280_read_calib,
> + .preinit = bmp280_preinit,
>
> .trigger_handler = bme280_trigger_handler,
> };
> diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h
> index 4e675401d61b..73516878d020 100644
> --- a/drivers/iio/pressure/bmp280.h
> +++ b/drivers/iio/pressure/bmp280.h
> @@ -205,6 +205,9 @@
> #define BMP280_REG_CONFIG 0xF5
> #define BMP280_REG_CTRL_MEAS 0xF4
> #define BMP280_REG_STATUS 0xF3
> +#define BMP280_REG_STATUS_IM_UPDATE BIT(0)
> +#define BMP280_REG_RESET 0xE0
> +#define BMP280_RST_SOFT_CMD 0xB6
>
> #define BMP280_REG_COMP_TEMP_START 0x88
> #define BMP280_COMP_TEMP_REG_COUNT 6
On Sun, Aug 25, 2024 at 09:04:16AM +0200, Christophe JAILLET wrote:
> Le 23/08/2024 à 20:17, Vasileios Amoiridis a écrit :
> > The BM(P/E)28x devices have an option for soft reset which is also
> > recommended by the Bosch Sensortech BME2 Sensor API to be used before the
> > initial configuration of the device.
> >
> > Link: https://github.com/boschsensortec/BME280_SensorAPI/blob/bme280_v3.5.1/bme280.c#L429
> > Signed-off-by: Vasileios Amoiridis <vassilisamir-Re5JQEeQqe8AvxtiuMwx3w@public.gmane.org>
> > ---
> > drivers/iio/pressure/bmp280-core.c | 26 ++++++++++++++++++++++++++
> > drivers/iio/pressure/bmp280.h | 3 +++
> > 2 files changed, 29 insertions(+)
> >
> > diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
> > index c23515048081..e01c9369bd67 100644
> > --- a/drivers/iio/pressure/bmp280-core.c
> > +++ b/drivers/iio/pressure/bmp280-core.c
> > @@ -965,6 +965,30 @@ static const unsigned long bme280_avail_scan_masks[] = {
> > 0
> > };
> > +static int bmp280_preinit(struct bmp280_data *data)
> > +{
> > + unsigned int reg;
> > + int ret;
> > +
> > + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD);
> > + if (ret)
> > + return dev_err_probe(data->dev, ret,
> > + "Failed to reset device.\n");
> > +
> > + usleep_range(data->start_up_time, data->start_up_time + 500);
> > +
> > + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®);
> > + if (ret)
> > + return dev_err_probe(data->dev, ret,
> > + "Failed to read status register.\n");
> > +
> > + if (reg & BMP280_REG_STATUS_IM_UPDATE)
> > + return dev_err_probe(data->dev, ret,
> > + "Failed to copy NVM contents.\n");
>
> ret is 0 at this point.
> Should a -E<something> be used instead?
>
> CJ
>
Hi Cristophe,
Yes, actually this could be an I/O error since we were not able to
copy the values back from the NVM device to the sensor.
Cheers,
Vasilis
> > +
> > + return 0;
> > +}
> > +
> > static int bmp280_chip_config(struct bmp280_data *data)
> > {
> > u8 osrs = FIELD_PREP(BMP280_OSRS_TEMP_MASK, data->oversampling_temp + 1) |
> > @@ -1082,6 +1106,7 @@ const struct bmp280_chip_info bmp280_chip_info = {
> > .read_temp = bmp280_read_temp,
> > .read_press = bmp280_read_press,
> > .read_calib = bmp280_read_calib,
> > + .preinit = bmp280_preinit,
> > .trigger_handler = bmp280_trigger_handler,
> > };
> > @@ -1202,6 +1227,7 @@ const struct bmp280_chip_info bme280_chip_info = {
> > .read_press = bmp280_read_press,
> > .read_humid = bme280_read_humid,
> > .read_calib = bme280_read_calib,
> > + .preinit = bmp280_preinit,
> > .trigger_handler = bme280_trigger_handler,
> > };
> > diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h
> > index 4e675401d61b..73516878d020 100644
> > --- a/drivers/iio/pressure/bmp280.h
> > +++ b/drivers/iio/pressure/bmp280.h
> > @@ -205,6 +205,9 @@
> > #define BMP280_REG_CONFIG 0xF5
> > #define BMP280_REG_CTRL_MEAS 0xF4
> > #define BMP280_REG_STATUS 0xF3
> > +#define BMP280_REG_STATUS_IM_UPDATE BIT(0)
> > +#define BMP280_REG_RESET 0xE0
> > +#define BMP280_RST_SOFT_CMD 0xB6
> > #define BMP280_REG_COMP_TEMP_START 0x88
> > #define BMP280_COMP_TEMP_REG_COUNT 6
>
On Fri, Aug 23, 2024 at 08:17:09PM +0200, Vasileios Amoiridis wrote:
> The BM(P/E)28x devices have an option for soft reset which is also
> recommended by the Bosch Sensortech BME2 Sensor API to be used before the
> initial configuration of the device.
...
> +static int bmp280_preinit(struct bmp280_data *data)
> +{
> + unsigned int reg;
> + int ret;
> +
> + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD);
> + if (ret)
> + return dev_err_probe(data->dev, ret,
> + "Failed to reset device.\n");
> + usleep_range(data->start_up_time, data->start_up_time + 500);
Seems long enough to warrant the comment. Also, why not fsleep()?
> + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®);
> + if (ret)
> + return dev_err_probe(data->dev, ret,
> + "Failed to read status register.\n");
> +
> + if (reg & BMP280_REG_STATUS_IM_UPDATE)
> + return dev_err_probe(data->dev, ret,
> + "Failed to copy NVM contents.\n");
> +
> + return 0;
> +}
--
With Best Regards,
Andy Shevchenko
On Fri, Aug 23, 2024 at 10:13:57PM +0300, Andy Shevchenko wrote:
> On Fri, Aug 23, 2024 at 08:17:09PM +0200, Vasileios Amoiridis wrote:
> > The BM(P/E)28x devices have an option for soft reset which is also
> > recommended by the Bosch Sensortech BME2 Sensor API to be used before the
> > initial configuration of the device.
>
> ...
>
> > +static int bmp280_preinit(struct bmp280_data *data)
> > +{
> > + unsigned int reg;
> > + int ret;
> > +
> > + ret = regmap_write(data->regmap, BMP280_REG_RESET, BMP280_RST_SOFT_CMD);
> > + if (ret)
> > + return dev_err_probe(data->dev, ret,
> > + "Failed to reset device.\n");
>
> > + usleep_range(data->start_up_time, data->start_up_time + 500);
>
> Seems long enough to warrant the comment. Also, why not fsleep()?
Hi Andy,
The datasheet of the sensor, and the published API from Bosch [1]
require the startup_time for this procedure, it's not something that
came up from my mind. That's why I didn't add any comment.
I was not aware of fsleep(), I think that it could be fine to use it.
Cheers,
Vasilis
[1]: https://github.com/boschsensortec/BME280_SensorAPI/blob/master/bme280.c#L677
>
> > + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®);
> > + if (ret)
> > + return dev_err_probe(data->dev, ret,
> > + "Failed to read status register.\n");
> > +
> > + if (reg & BMP280_REG_STATUS_IM_UPDATE)
> > + return dev_err_probe(data->dev, ret,
> > + "Failed to copy NVM contents.\n");
> > +
> > + return 0;
> > +}
>
>
> --
> With Best Regards,
> Andy Shevchenko
>
>
On Sat, Aug 24, 2024 at 01:16:14PM +0200, Vasileios Amoiridis wrote: > On Fri, Aug 23, 2024 at 10:13:57PM +0300, Andy Shevchenko wrote: > > On Fri, Aug 23, 2024 at 08:17:09PM +0200, Vasileios Amoiridis wrote: ... > > > + usleep_range(data->start_up_time, data->start_up_time + 500); > > > > Seems long enough to warrant the comment. Also, why not fsleep()? > > The datasheet of the sensor, and the published API from Bosch [1] > require the startup_time for this procedure, it's not something that > came up from my mind. That's why I didn't add any comment. The comment usually needed on the basis of how long we have to sleep. To me ~1ms warrants that as it's long enough timeout on modern (GHz frequency range) CPUs. -- With Best Regards, Andy Shevchenko