[PATCH v1 02/17] iio: chemical: bme680: Fix calibration data variable

Vasileios Amoiridis posted 17 patches 1 year, 8 months ago
There is a newer version of this series
[PATCH v1 02/17] iio: chemical: bme680: Fix calibration data variable
Posted by Vasileios Amoiridis 1 year, 8 months ago
According to the BME68x Sensor API [1], the h6 calibration
data variable should be an unsigned integer of size 8.

[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L789
Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
---
 drivers/iio/chemical/bme680_core.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
index 2c40c13fe97a..812829841733 100644
--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -38,7 +38,7 @@ struct bme680_calib {
 	s8  par_h3;
 	s8  par_h4;
 	s8  par_h5;
-	s8  par_h6;
+	u8  par_h6;
 	s8  par_h7;
 	s8  par_gh1;
 	s16 par_gh2;
-- 
2.25.1