From: Li Nan <linan122@huawei.com>
Changes in v2:
- Add RAID_1_10_NAME to distinguish name between raid1 and raid10.
Li Nan (2):
md: factor out a helper exceed_read_errors() to check read_errors
md/raid1: support read error check
drivers/md/raid1-10.c | 54 +++++++++++++++++++++++++++++++++++++++++++
drivers/md/raid1.c | 18 +++++++++++----
drivers/md/raid10.c | 49 +++------------------------------------
3 files changed, 70 insertions(+), 51 deletions(-)
--
2.39.2
Re: [PATCH v2 0/2] support read error check in raid1
Posted by
Song Liu
2 years ago
On Thu, Dec 14, 2023 at 6:40 PM <linan666@huaweicloud.com> wrote:
>
> From: Li Nan <linan122@huawei.com>
>
> Changes in v2:
> - Add RAID_1_10_NAME to distinguish name between raid1 and raid10.
>
> Li Nan (2):
> md: factor out a helper exceed_read_errors() to check read_errors
> md/raid1: support read error check
Applied to md-next. Thanks,
Song