[PATCH v2] arm64: dts: imx8mp: use correct clock for eqos timestamping counter

Johannes Zink posted 1 patch 2 years, 1 month ago
arch/arm64/boot/dts/freescale/imx8mp.dtsi | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)
[PATCH v2] arm64: dts: imx8mp: use correct clock for eqos timestamping counter
Posted by Johannes Zink 2 years, 1 month ago
The i.MX8MP Reference Manual rev 1 06/2021, section 11.7.2.5 "Timestamp
Support" indicates the PTP timestamp clock expects a typical frequency
of 125MHz.

As this also improves the precision of the measured timestamps: assign
appropriate 125MHz Clock parent. As no one except the timestamping
counter uses this clock, there are no side-effects of this change in
other peripherals.

Signed-off-by: Johannes Zink <j.zink@pengutronix.de>
---
Changes in v2:
- not only set assigned-clock-parents but alkso assigned-clock-rates for
  IMX8MP_CLK_ENET_QOS_TIMER to 125MHz (found by Fabio's review -
  thanks!)
- Link to v1: https://lore.kernel.org/r/20230719-imx8mp_enet_qos_use_125mhz_clock-v1-1-782c9ac6e121@pengutronix.de
---
Changes:
  v1 -> v2: Worked in Fabio's Feedback - Thank you for your review!
             - not only set assigned clock parent to 125MHz but also
	       set the assigned clock rate of IMX8MP_CLK_ENET_QOS_TIMER
	       to 125MHz
---
 arch/arm64/boot/dts/freescale/imx8mp.dtsi | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/arch/arm64/boot/dts/freescale/imx8mp.dtsi b/arch/arm64/boot/dts/freescale/imx8mp.dtsi
index 6f2f50e1639c..84ecf07affb3 100644
--- a/arch/arm64/boot/dts/freescale/imx8mp.dtsi
+++ b/arch/arm64/boot/dts/freescale/imx8mp.dtsi
@@ -1334,9 +1334,9 @@ eqos: ethernet@30bf0000 {
 						  <&clk IMX8MP_CLK_ENET_QOS_TIMER>,
 						  <&clk IMX8MP_CLK_ENET_QOS>;
 				assigned-clock-parents = <&clk IMX8MP_SYS_PLL1_266M>,
-							 <&clk IMX8MP_SYS_PLL2_100M>,
+							 <&clk IMX8MP_SYS_PLL2_125M>,
 							 <&clk IMX8MP_SYS_PLL2_125M>;
-				assigned-clock-rates = <0>, <100000000>, <125000000>;
+				assigned-clock-rates = <0>, <125000000>, <125000000>;
 				nvmem-cells = <&eth_mac2>;
 				nvmem-cell-names = "mac-address";
 				intf_mode = <&gpr 0x4>;

---
base-commit: ba345b77fae7054d0cbd033283c47033e45db6d8
change-id: 20230719-imx8mp_enet_qos_use_125mhz_clock-1c4611c979ba

Best regards,
-- 
Johannes Zink <j.zink@pengutronix.de>
Re: [PATCH v2] arm64: dts: imx8mp: use correct clock for eqos timestamping counter
Posted by Fabio Estevam 2 years, 1 month ago
On Fri, Jul 21, 2023 at 12:51 AM Johannes Zink <j.zink@pengutronix.de> wrote:
>
> The i.MX8MP Reference Manual rev 1 06/2021, section 11.7.2.5 "Timestamp
> Support" indicates the PTP timestamp clock expects a typical frequency
> of 125MHz.
>
> As this also improves the precision of the measured timestamps: assign
> appropriate 125MHz Clock parent. As no one except the timestamping
> counter uses this clock, there are no side-effects of this change in
> other peripherals.
>
> Signed-off-by: Johannes Zink <j.zink@pengutronix.de>

Reviewed-by: Fabio Estevam <festevam@gmail.com>
Re: [PATCH v2] arm64: dts: imx8mp: use correct clock for eqos timestamping counter
Posted by Johannes Zink 2 years, 1 month ago
Hi everyone,

On 7/22/23 03:49, Fabio Estevam wrote:
> On Fri, Jul 21, 2023 at 12:51 AM Johannes Zink <j.zink@pengutronix.de> wrote:
>>
>> The i.MX8MP Reference Manual rev 1 06/2021, section 11.7.2.5 "Timestamp
>> Support" indicates the PTP timestamp clock expects a typical frequency
>> of 125MHz.
>>
>> As this also improves the precision of the measured timestamps: assign
>> appropriate 125MHz Clock parent. As no one except the timestamping
>> counter uses this clock, there are no side-effects of this change in
>> other peripherals.
>>
>> Signed-off-by: Johannes Zink <j.zink@pengutronix.de>
> 
> Reviewed-by: Fabio Estevam <festevam@gmail.com>
> 
> 

please scratch this patch, the PTP Timestamping clock cannot be supplied with a 
125MHz clock, there is no 125MHz source in the MUX input and I misinterpreted 
the clocksummary when testing this patch.

Sorry for the noise,
Johannes


-- 
Pengutronix e.K.                | Johannes Zink                  |
Steuerwalder Str. 21            | https://www.pengutronix.de/    |
31137 Hildesheim, Germany       | Phone: +49-5121-206917-0       |
Amtsgericht Hildesheim, HRA 2686| Fax:   +49-5121-206917-5555    |