drivers/hwmon/pmbus/pmbus_core.c | 88 ++++++++++++++++++++++++++++++++ 1 file changed, 88 insertions(+)
From: Patrick Rudolph <patrick.rudolph@9elements.com>
Add get_status for pmbus_regulator_ops.
Changes:
- use lock throughout the function
- Avoid line continuation upto 100 column
- Optimize use of & and | operator
- Check for VOUT, IOUT, TEMPERATURE bit in status word before checking
respective status register for fault.
- Report regulator current status.
Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
Signed-off-by: Naresh Solanki <Naresh.Solanki@9elements.com>
---
drivers/hwmon/pmbus/pmbus_core.c | 88 ++++++++++++++++++++++++++++++++
1 file changed, 88 insertions(+)
diff --git a/drivers/hwmon/pmbus/pmbus_core.c b/drivers/hwmon/pmbus/pmbus_core.c
index 7ec04934747e..f7a322d5b453 100644
--- a/drivers/hwmon/pmbus/pmbus_core.c
+++ b/drivers/hwmon/pmbus/pmbus_core.c
@@ -2851,6 +2851,93 @@ static int pmbus_regulator_get_error_flags(struct regulator_dev *rdev, unsigned
return 0;
}
+static int pmbus_regulator_get_status(struct regulator_dev *rdev)
+{
+ struct device *dev = rdev_get_dev(rdev);
+ struct i2c_client *client = to_i2c_client(dev->parent);
+ struct pmbus_data *data = i2c_get_clientdata(client);
+ u8 page = rdev_get_id(rdev);
+ int status, status2, ret;
+
+ mutex_lock(&data->update_lock);
+ status = pmbus_get_status(client, page, PMBUS_STATUS_WORD);
+ if (status < 0) {
+ ret = status;
+ goto unlock;
+ }
+
+ if (status & PB_STATUS_OFF) {
+ ret = REGULATOR_STATUS_OFF;
+ goto unlock;
+ }
+
+ /* If regulator is ON & reports power good then return ON */
+ if (!(status & PB_STATUS_POWER_GOOD_N)) {
+ ret = REGULATOR_STATUS_ON;
+ goto unlock;
+ }
+
+ if (status & (PB_STATUS_VIN_UV | PB_STATUS_IOUT_OC | PB_STATUS_VOUT_OV |
+ PB_STATUS_UNKNOWN)){
+ ret = REGULATOR_STATUS_ERROR;
+ goto unlock;
+ }
+
+ if (status & PB_STATUS_VOUT && data->info->func[page] & PMBUS_HAVE_STATUS_VOUT) {
+ status2 = _pmbus_read_byte_data(client, page,
+ PMBUS_STATUS_VOUT);
+ if (status2 < 0) {
+ ret = status2;
+ goto unlock;
+ }
+ if (status2 & (PB_VOLTAGE_OV_FAULT | PB_VOLTAGE_UV_FAULT)) {
+ ret = REGULATOR_STATUS_ERROR;
+ goto unlock;
+ }
+ }
+
+ if (status & PB_STATUS_IOUT_POUT && data->info->func[page] & PMBUS_HAVE_STATUS_IOUT) {
+ status2 = _pmbus_read_byte_data(client, page, PMBUS_STATUS_IOUT);
+ if (status2 < 0) {
+ ret = status2;
+ goto unlock;
+ }
+ if (status2 & (PB_POUT_OP_FAULT | PB_IOUT_UC_FAULT | PB_IOUT_OC_LV_FAULT |
+ PB_IOUT_OC_FAULT)) {
+ ret = REGULATOR_STATUS_ERROR;
+ goto unlock;
+ }
+ }
+
+ if (status & PB_STATUS_INPUT && data->info->func[page] & PMBUS_HAVE_STATUS_INPUT) {
+ status2 = _pmbus_read_byte_data(client, page, PMBUS_STATUS_INPUT);
+ if (status2 < 0) {
+ ret = status2;
+ goto unlock;
+ }
+ if (status2 & (PB_IIN_OC_FAULT | PB_VOLTAGE_OV_FAULT | PB_VOLTAGE_UV_FAULT)) {
+ ret = REGULATOR_STATUS_ERROR;
+ goto unlock;
+ }
+ }
+
+ if (status & PB_STATUS_TEMPERATURE && data->info->func[page] & PMBUS_HAVE_STATUS_TEMP) {
+ status2 = _pmbus_read_byte_data(client, page, PMBUS_STATUS_TEMPERATURE);
+ if (status2 < 0) {
+ ret = status2;
+ goto unlock;
+ }
+ if (status2 & (PB_TEMP_UT_FAULT | PB_TEMP_OT_FAULT)) {
+ ret = REGULATOR_STATUS_ERROR;
+ goto unlock;
+ }
+ }
+
+unlock:
+ mutex_unlock(&data->update_lock);
+ return ret;
+}
+
static int pmbus_regulator_get_low_margin(struct i2c_client *client, int page)
{
struct pmbus_data *data = i2c_get_clientdata(client);
@@ -2991,6 +3078,7 @@ const struct regulator_ops pmbus_regulator_ops = {
.disable = pmbus_regulator_disable,
.is_enabled = pmbus_regulator_is_enabled,
.get_error_flags = pmbus_regulator_get_error_flags,
+ .get_status = pmbus_regulator_get_status,
.get_voltage = pmbus_regulator_get_voltage,
.set_voltage = pmbus_regulator_set_voltage,
.list_voltage = pmbus_regulator_list_voltage,
base-commit: 27fea302952d8c90cafbdbee96bafeca03544401
--
2.37.3
On Sat, Nov 19, 2022 at 07:25:16PM +0100, Naresh Solanki wrote: > From: Patrick Rudolph <patrick.rudolph@9elements.com> > > Add get_status for pmbus_regulator_ops. > > Changes: > - use lock throughout the function > - Avoid line continuation upto 100 column > - Optimize use of & and | operator > - Check for VOUT, IOUT, TEMPERATURE bit in status word before checking > respective status register for fault. > - Report regulator current status. > Change log should be after '---' Also, when looking into this, I realized that we already have pmbus_regulator_get_error_flags() which has somewhat overlapping functionality. Would it be possible to utilize that function to get the error status instead of more or less hand-coding it ? Thanks, Guenter
Hi Guenter, On 20-11-2022 07:44 pm, Guenter Roeck wrote: > On Sat, Nov 19, 2022 at 07:25:16PM +0100, Naresh Solanki wrote: >> From: Patrick Rudolph <patrick.rudolph@9elements.com> >> >> Add get_status for pmbus_regulator_ops. >> >> Changes: >> - use lock throughout the function >> - Avoid line continuation upto 100 column >> - Optimize use of & and | operator >> - Check for VOUT, IOUT, TEMPERATURE bit in status word before checking >> respective status register for fault. >> - Report regulator current status. >> > Change log should be after '---' Sure > > Also, when looking into this, I realized that we already have > pmbus_regulator_get_error_flags() which has somewhat overlapping > functionality. Would it be possible to utilize that function to get > the error status instead of more or less hand-coding it ? Sure. But looking at get_status scope, I feel that we are already checking the following: 1. Check if regulator is off & yes then return off 2. If not off then it should be on & has power good then return on 3. If no power good then this itself is error condition so return error. Decoding status register for fault just double confirms that & may not be needed in get_status unless we are going to print or utilize the error bit information in some other way but that is out of scope of get_status call unless I missed something. Does this approach makes sense ? > > Thanks, > Guenter
© 2016 - 2026 Red Hat, Inc.