Add common fan properties bindings to a schema.
Bindings for fan controllers can reference the common schema for the
fan
child nodes:
patternProperties:
"^fan@[0-2]":
type: object
$ref: fan-common.yaml#
Signed-off-by: Naresh Solanki <Naresh.Solanki@9elements.com>
---
.../devicetree/bindings/hwmon/fan-common.yaml | 48 +++++++++++++++++++
1 file changed, 48 insertions(+)
create mode 100644 Documentation/devicetree/bindings/hwmon/fan-common.yaml
diff --git a/Documentation/devicetree/bindings/hwmon/fan-common.yaml b/Documentation/devicetree/bindings/hwmon/fan-common.yaml
new file mode 100644
index 000000000000..224f5013c93f
--- /dev/null
+++ b/Documentation/devicetree/bindings/hwmon/fan-common.yaml
@@ -0,0 +1,48 @@
+# SPDX-License-Identifier: GPL-2.0-or-later OR BSD-2-Clause
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/hwmon/fan-common.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Common fan properties
+
+maintainers:
+ - Naresh Solanki <naresh.solanki@9elements.com>
+
+properties:
+ max-rpm:
+ description:
+ Max RPM supported by fan.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ pulses-per-revolution:
+ description:
+ The number of pulse from fan sensor per revolution.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ default-rpm:
+ description:
+ Target RPM the fan should be configured during driver probe.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ pwm-frequency:
+ description:
+ PWM frequency for fan in Hertz(Hz).
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ pwm-polarity-inverse:
+ description:
+ Inverse PWM polarity for fan.
+ type: boolean
+
+ label:
+ description:
+ Optional fan label
+
+ fan-supply:
+ description:
+ Power supply for fan.
+
+additionalProperties: true
+
+...
base-commit: 0cf46a653bdae56683fece68dc50340f7520e6c4
--
2.37.3
On Thu, Oct 13, 2022 at 11:48:36AM +0200, Naresh Solanki wrote: > Add common fan properties bindings to a schema. > > Bindings for fan controllers can reference the common schema for the > fan > > child nodes: > > patternProperties: > "^fan@[0-2]": > type: object > $ref: fan-common.yaml# > > Signed-off-by: Naresh Solanki <Naresh.Solanki@9elements.com> > --- > .../devicetree/bindings/hwmon/fan-common.yaml | 48 +++++++++++++++++++ > 1 file changed, 48 insertions(+) > create mode 100644 Documentation/devicetree/bindings/hwmon/fan-common.yaml > > diff --git a/Documentation/devicetree/bindings/hwmon/fan-common.yaml b/Documentation/devicetree/bindings/hwmon/fan-common.yaml > new file mode 100644 > index 000000000000..224f5013c93f > --- /dev/null > +++ b/Documentation/devicetree/bindings/hwmon/fan-common.yaml > @@ -0,0 +1,48 @@ > +# SPDX-License-Identifier: GPL-2.0-or-later OR BSD-2-Clause > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/hwmon/fan-common.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: Common fan properties > + > +maintainers: > + - Naresh Solanki <naresh.solanki@9elements.com> > + > +properties: > + max-rpm: > + description: > + Max RPM supported by fan. > + $ref: /schemas/types.yaml#/definitions/uint32 > + > + pulses-per-revolution: > + description: > + The number of pulse from fan sensor per revolution. > + $ref: /schemas/types.yaml#/definitions/uint32 > + > + default-rpm: > + description: > + Target RPM the fan should be configured during driver probe. So if we unload and reload the driver module, it should go back to the default? I think it is really, 'target RPM if not already configured' which could be keep the setting from a register (e.g. what the bootloader set) or perhaps you already have temperature information to use... > + $ref: /schemas/types.yaml#/definitions/uint32 > + pwm-frequency: > + description: > + PWM frequency for fan in Hertz(Hz). > + $ref: /schemas/types.yaml#/definitions/uint32 > + > + pwm-polarity-inverse: > + description: > + Inverse PWM polarity for fan. > + type: boolean As I said before, the PWM binding handles these 2 settings. Use it. Yes, it's a bit of an overkill when the child is the consumer of the parent. Until some 'clever' h/w engineer decides to use one of the PWMs for something else like a backlight. Rob
On 24-10-2022 09:48 pm, Rob Herring wrote: > So if we unload and reload the driver module, it should go back to the > default? This is RPM to be set during probe if desired. > > I think it is really, 'target RPM if not already configured' which could > be keep the setting from a register (e.g. what the bootloader set) or > perhaps you already have temperature information to use... Yes. missed it. It should be target-rpm will correct this. in next version. > >> + $ref: /schemas/types.yaml#/definitions/uint32 >> + pwm-frequency: >> + description: >> + PWM frequency for fan in Hertz(Hz). >> + $ref: /schemas/types.yaml#/definitions/uint32 >> + >> + pwm-polarity-inverse: >> + description: >> + Inverse PWM polarity for fan. >> + type: boolean > As I said before, the PWM binding handles these 2 settings. Use it. Yes, > it's a bit of an overkill when the child is the consumer of the parent. > Until some 'clever' h/w engineer decides to use one of the PWMs for > something else like a backlight. I would like you to consider this as something recommended by fan datasheet for the given fan instance. This info can be used by fan controller driver to configure PWM source/provider accordingly. If you still feel that may not make sense then I'll remove this property. Thanks, Naresh
On Tue, Oct 25, 2022 at 4:16 AM Naresh Solanki
<naresh.solanki@9elements.com> wrote:
>
>
>
> On 24-10-2022 09:48 pm, Rob Herring wrote:
> > So if we unload and reload the driver module, it should go back to the
> > default?
> This is RPM to be set during probe if desired.
> >
> > I think it is really, 'target RPM if not already configured' which could
> > be keep the setting from a register (e.g. what the bootloader set) or
> > perhaps you already have temperature information to use...
> Yes. missed it. It should be target-rpm will correct this. in next version.
> >
> >> + $ref: /schemas/types.yaml#/definitions/uint32
> >> + pwm-frequency:
> >> + description:
> >> + PWM frequency for fan in Hertz(Hz).
> >> + $ref: /schemas/types.yaml#/definitions/uint32
> >> +
> >> + pwm-polarity-inverse:
> >> + description:
> >> + Inverse PWM polarity for fan.
> >> + type: boolean
> > As I said before, the PWM binding handles these 2 settings. Use it. Yes,
> > it's a bit of an overkill when the child is the consumer of the parent.
> > Until some 'clever' h/w engineer decides to use one of the PWMs for
> > something else like a backlight.
> I would like you to consider this as something recommended by fan
> datasheet for the given fan instance.
> This info can be used by fan controller driver to configure PWM
> source/provider accordingly.
>
> If you still feel that may not make sense then I'll remove this property.
You evidently don't understand my comments. My suggestion is to do this:
fanc: fan-controller {
#pwm-cells = <3>;
...
fan {
pwms = <&fanc 0 500000 PWM_POLARITY_INVERTED>;
...
};
};
0 is PWM number and 500000 is the PWM frequency. The 3rd cell are per
consumer flags. See pwm.txt for more details.
Rob
Hi Rob,
On 26-10-2022 07:07 pm, Rob Herring wrote:
> fanc: fan-controller {
> #pwm-cells = <3>;
> ...
>
> fan {
> pwms = <&fanc 0 500000 PWM_POLARITY_INVERTED>;
> ...
> };
> };
>
> 0 is PWM number and 500000 is the PWM frequency. The 3rd cell are per
> consumer flags. See pwm.txt for more details.
Did the implementation & while testing getting the below err:
[63.626505] max6639 166-002e: failed to create device link to 166-002e
On Mon, Oct 31, 2022 at 01:35:09PM +0530, Naresh Solanki wrote:
> Hi Rob,
>
> On 26-10-2022 07:07 pm, Rob Herring wrote:
> > fanc: fan-controller {
> > #pwm-cells = <3>;
> > ...
> >
> > fan {
> > pwms = <&fanc 0 500000 PWM_POLARITY_INVERTED>;
> > ...
> > };
> > };
> >
> > 0 is PWM number and 500000 is the PWM frequency. The 3rd cell are per
> > consumer flags. See pwm.txt for more details.
>
> Did the implementation & while testing getting the below err:
> [63.626505] max6639 166-002e: failed to create device link to 166-002e
Does turning off fw_devlink help (fw_devlink=off)?
Rob
Hi Rob,
On 02-11-2022 12:14 am, Rob Herring wrote:
> On Mon, Oct 31, 2022 at 01:35:09PM +0530, Naresh Solanki wrote:
>> Hi Rob,
>>
>> On 26-10-2022 07:07 pm, Rob Herring wrote:
>>> fanc: fan-controller {
>>> #pwm-cells = <3>;
>>> ...
>>>
>>> fan {
>>> pwms = <&fanc 0 500000 PWM_POLARITY_INVERTED>;
>>> ...
>>> };
>>> };
>>>
>>> 0 is PWM number and 500000 is the PWM frequency. The 3rd cell are per
>>> consumer flags. See pwm.txt for more details.
>>
>> Did the implementation & while testing getting the below err:
>> [63.626505] max6639 166-002e: failed to create device link to 166-002e
>
> Does turning off fw_devlink help (fw_devlink=off)?
Will supplier == consumer, device link creation fails.
Not sure what is best approach but not creating device link in this
scenario help & for that below additional changes needed in pwm core.
diff --git a/drivers/pwm/core.c b/drivers/pwm/core.c
index 4527f09a5c50..afea51c49138 100644
--- a/drivers/pwm/core.c
+++ b/drivers/pwm/core.c
@@ -730,6 +730,12 @@ static struct device_link
*pwm_device_link_add(struct device *dev,
return NULL;
}
+ /*
+ * Do not attempt to create link if consumer itself is supplier.
+ */
+ if (dev == pwm->chip->dev)
+ return 0;
+
dl = device_link_add(dev, pwm->chip->dev, DL_FLAG_AUTOREMOVE_CONSUMER);
if (!dl) {
dev_err(dev, "failed to create device link to %s\n",
Regards,
Naresh
Hi Rob, On 02-11-2022 12:14 am, Rob Herring wrote: > Does turning off fw_devlink help (fw_devlink=off)? This didn't bring any difference for the error. Failing due to same consumer & supplier. Returning from here: https://github.com/torvalds/linux/blob/master/drivers/base/core.c#L702 Also this can cause return: https://github.com/torvalds/linux/blob/master/drivers/base/core.c#L732 Regards, Naresh