drivers/power/reset/Kconfig | 1 + 1 file changed, 1 insertion(+)
The Toradex Embedded Controller is currently only present on Toradex
SMARC iMX8MP and iMX95 SoMs. Hence add a dependency on ARCH_MXC, to
prevent asking the user about this driver when configuring a kernel
without NXP i.MX SoC family support.
Fixes: 18672fe12367ed44 ("power: reset: add Toradex Embedded Controller")
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
---
drivers/power/reset/Kconfig | 1 +
1 file changed, 1 insertion(+)
diff --git a/drivers/power/reset/Kconfig b/drivers/power/reset/Kconfig
index 5ce402ff71964f59..1a17c5192818de1e 100644
--- a/drivers/power/reset/Kconfig
+++ b/drivers/power/reset/Kconfig
@@ -218,6 +218,7 @@ config POWER_RESET_ST
config POWER_RESET_TORADEX_EC
tristate "Toradex Embedded Controller power-off and reset driver"
+ depends on ARCH_MXC || COMPILE_TEST
depends on I2C
select REGMAP_I2C
help
--
2.43.0
On Tue, 06 May 2025 15:01:27 +0200, Geert Uytterhoeven wrote:
> The Toradex Embedded Controller is currently only present on Toradex
> SMARC iMX8MP and iMX95 SoMs. Hence add a dependency on ARCH_MXC, to
> prevent asking the user about this driver when configuring a kernel
> without NXP i.MX SoC family support.
>
>
Applied, thanks!
[1/1] power: reset: POWER_RESET_TORADEX_EC should depend on ARCH_MXC
commit: 22e4d29f081df8a10f1c062d3d952bb876eb9bdc
Best regards,
--
Sebastian Reichel <sebastian.reichel@collabora.com>
On 06/05/2025 15:01, Geert Uytterhoeven wrote:
> The Toradex Embedded Controller is currently only present on Toradex
> SMARC iMX8MP and iMX95 SoMs. Hence add a dependency on ARCH_MXC, to
> prevent asking the user about this driver when configuring a kernel
> without NXP i.MX SoC family support.
>
> Fixes: 18672fe12367ed44 ("power: reset: add Toradex Embedded Controller")
> Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
> ---
> drivers/power/reset/Kconfig | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/drivers/power/reset/Kconfig b/drivers/power/reset/Kconfig
> index 5ce402ff71964f59..1a17c5192818de1e 100644
> --- a/drivers/power/reset/Kconfig
> +++ b/drivers/power/reset/Kconfig
> @@ -218,6 +218,7 @@ config POWER_RESET_ST
>
> config POWER_RESET_TORADEX_EC
> tristate "Toradex Embedded Controller power-off and reset driver"
> + depends on ARCH_MXC || COMPILE_TEST
> depends on I2C
> select REGMAP_I2C
> help
The default is 'N', and the EC is just an I2C device, unrelated to ARCH_MXC.
Is it really annoying if the user is asked about this driver during
configuration? Or is it just normal?
Wouldn't there be a better way to handle this?