drivers/base/cacheinfo.c | 23 ++++++++- include/linux/cacheinfo.h | 1 +- include/linux/sched/topology.h | 7 ++- kernel/sched/topology.c | 98 +++++++++++++++++++++++++++++++-- 4 files changed, 126 insertions(+), 3 deletions(-)
The following commit has been merged into the sched/core branch of tip:
Commit-ID: 7030513a08776b2ca70fccd5dfddf7bb5c5c88ba
Gitweb: https://git.kernel.org/tip/7030513a08776b2ca70fccd5dfddf7bb5c5c88ba
Author: Chen Yu <yu.c.chen@intel.com>
AuthorDate: Wed, 13 May 2026 13:39:15 -07:00
Committer: Peter Zijlstra <peterz@infradead.org>
CommitterDate: Mon, 18 May 2026 21:33:15 +02:00
sched/cache: Calculate the LLC size and store it in sched_domain
Cache aware scheduling needs to know the LLC size that a process
can use, so as to avoid memory-intensive tasks from being
over-aggregated on a single LLC.
Introduce a preparation patch to add get_effective_llc_bytes() to
get the LLC size that a CPU can use. The function can be further
enhanced by subtracting the LLC cache ways reserved by resctrl
(CAT in Intel RDT, etc).
Suggested-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Signed-off-by: Chen Yu <yu.c.chen@intel.com>
Co-developed-by: Tim Chen <tim.c.chen@linux.intel.com>
Signed-off-by: Tim Chen <tim.c.chen@linux.intel.com>
Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Tested-by: Tingyin Duan <tingyin.duan@gmail.com>
Link: https://patch.msgid.link/37afee09ff608034da0ce149e72d33b6f4698edf.1778703694.git.tim.c.chen@linux.intel.com
---
drivers/base/cacheinfo.c | 23 ++++++++-
include/linux/cacheinfo.h | 1 +-
include/linux/sched/topology.h | 7 ++-
kernel/sched/topology.c | 98 +++++++++++++++++++++++++++++++--
4 files changed, 126 insertions(+), 3 deletions(-)
diff --git a/drivers/base/cacheinfo.c b/drivers/base/cacheinfo.c
index 391ac5e..70701d3 100644
--- a/drivers/base/cacheinfo.c
+++ b/drivers/base/cacheinfo.c
@@ -17,6 +17,7 @@
#include <linux/init.h>
#include <linux/of.h>
#include <linux/sched.h>
+#include <linux/sched/topology.h>
#include <linux/slab.h>
#include <linux/smp.h>
#include <linux/sysfs.h>
@@ -68,6 +69,24 @@ bool last_level_cache_is_valid(unsigned int cpu)
}
+/*
+ * Get the cacheinfo of the LLC associated with @cpu.
+ * Derived from update_per_cpu_data_slice_size_cpu().
+ */
+struct cacheinfo *get_cpu_cacheinfo_llc(unsigned int cpu)
+{
+ struct cacheinfo *llc;
+
+ if (!last_level_cache_is_valid(cpu))
+ return NULL;
+
+ llc = per_cpu_cacheinfo_idx(cpu, cache_leaves(cpu) - 1);
+ if (llc->type != CACHE_TYPE_DATA && llc->type != CACHE_TYPE_UNIFIED)
+ return NULL;
+
+ return llc;
+}
+
bool last_level_cache_is_shared(unsigned int cpu_x, unsigned int cpu_y)
{
struct cacheinfo *llc_x, *llc_y;
@@ -1018,6 +1037,7 @@ static int cacheinfo_cpu_online(unsigned int cpu)
goto err;
if (cpu_map_shared_cache(true, cpu, &cpu_map))
update_per_cpu_data_slice_size(true, cpu, cpu_map);
+ sched_update_llc_bytes(cpu);
return 0;
err:
free_cache_attributes(cpu);
@@ -1036,6 +1056,9 @@ static int cacheinfo_cpu_pre_down(unsigned int cpu)
free_cache_attributes(cpu);
if (nr_shared > 1)
update_per_cpu_data_slice_size(false, cpu, cpu_map);
+
+ sched_update_llc_bytes(cpu);
+
return 0;
}
diff --git a/include/linux/cacheinfo.h b/include/linux/cacheinfo.h
index c8f4f0a..fc879ac 100644
--- a/include/linux/cacheinfo.h
+++ b/include/linux/cacheinfo.h
@@ -89,6 +89,7 @@ int populate_cache_leaves(unsigned int cpu);
int cache_setup_acpi(unsigned int cpu);
bool last_level_cache_is_valid(unsigned int cpu);
bool last_level_cache_is_shared(unsigned int cpu_x, unsigned int cpu_y);
+struct cacheinfo *get_cpu_cacheinfo_llc(unsigned int cpu);
int fetch_cache_info(unsigned int cpu);
int detect_cache_attributes(unsigned int cpu);
#ifndef CONFIG_ACPI_PPTT
diff --git a/include/linux/sched/topology.h b/include/linux/sched/topology.h
index 0036d6b..fe09d32 100644
--- a/include/linux/sched/topology.h
+++ b/include/linux/sched/topology.h
@@ -106,6 +106,7 @@ struct sched_domain {
#ifdef CONFIG_SCHED_CACHE
unsigned int llc_max;
unsigned int *llc_counts __counted_by_ptr(llc_max);
+ unsigned long llc_bytes;
#endif
#ifdef CONFIG_SCHEDSTATS
@@ -265,4 +266,10 @@ static inline int task_node(const struct task_struct *p)
return cpu_to_node(task_cpu(p));
}
+#ifdef CONFIG_SCHED_CACHE
+extern void sched_update_llc_bytes(unsigned int cpu);
+#else
+static inline void sched_update_llc_bytes(unsigned int cpu) { }
+#endif
+
#endif /* _LINUX_SCHED_TOPOLOGY_H */
diff --git a/kernel/sched/topology.c b/kernel/sched/topology.c
index 9fc9934..7248a72 100644
--- a/kernel/sched/topology.c
+++ b/kernel/sched/topology.c
@@ -776,9 +776,11 @@ cpu_attach_domain(struct sched_domain *sd, struct root_domain *rd, int cpu)
/* move buffer to parent as child is being destroyed */
sd->llc_counts = tmp->llc_counts;
sd->llc_max = tmp->llc_max;
+ sd->llc_bytes = tmp->llc_bytes;
/* make sure destroy_sched_domain() does not free it */
tmp->llc_counts = NULL;
tmp->llc_max = 0;
+ tmp->llc_bytes = 0;
#endif
/*
* sched groups hold the flags of the child sched
@@ -831,10 +833,42 @@ DEFINE_STATIC_KEY_FALSE(sched_cache_active);
/* user wants cache aware scheduling [0 or 1] */
int sysctl_sched_cache_user = 1;
+/*
+ * Get the effective LLC size in bytes that @cpu's bottom sched_domain
+ * can use. A CPU within a cpuset partition can only use a proportion
+ * of the physical LLC, scaled by the ratio of the partition's span
+ * weight to the hardware LLC sharing weight. @sd should be the
+ * topmost domain with SD_SHARE_LLC.
+ *
+ * Returns 0 if cacheinfo is not yet populated. This happens during
+ * early boot when build_sched_domains() runs before the generic
+ * cacheinfo framework has been initialized (cacheinfo_cpu_online()
+ * is a device_initcall cpuhp callback). In that case,
+ * cacheinfo_cpu_online() will later call sched_update_llc_bytes()
+ * to fill in the bottom domain's llc_bytes once the cache attributes
+ * are available.
+ */
+static unsigned long get_effective_llc_bytes(int cpu,
+ struct sched_domain *sd)
+{
+ struct cacheinfo *ci;
+ unsigned int hw_weight;
+
+ ci = get_cpu_cacheinfo_llc(cpu);
+ if (!ci)
+ return 0;
+
+ hw_weight = cpumask_weight(&ci->shared_cpu_map);
+ if (!hw_weight)
+ return 0;
+
+ return div_u64((u64)ci->size * sd->span_weight, hw_weight);
+}
+
static bool alloc_sd_llc(const struct cpumask *cpu_map,
struct s_data *d)
{
- struct sched_domain *sd;
+ struct sched_domain *sd, *top_llc, *parent;
unsigned int *p;
int i;
@@ -848,8 +882,24 @@ static bool alloc_sd_llc(const struct cpumask *cpu_map,
if (!p)
goto err;
- sd->llc_max = max_lid + 1;
- sd->llc_counts = p;
+ top_llc = sd;
+ /*
+ * Find the topmost SD_SHARE_LLC domain.
+ * Not yet attached to the CPU, so per_cpu(sd_llc, i)
+ * can not be used.
+ */
+ while ((parent = rcu_dereference_protected(top_llc->parent, true)) &&
+ (parent->flags & SD_SHARE_LLC))
+ top_llc = parent;
+
+ if (top_llc->flags & SD_SHARE_LLC) {
+ sd->llc_max = max_lid + 1;
+ sd->llc_counts = p;
+ sd->llc_bytes = get_effective_llc_bytes(i, top_llc);
+ } else {
+ /* avoid memory leak */
+ kfree(p);
+ }
}
return true;
@@ -860,6 +910,7 @@ err:
kfree(sd->llc_counts);
sd->llc_counts = NULL;
sd->llc_max = 0;
+ sd->llc_bytes = 0;
}
}
@@ -919,6 +970,47 @@ void sched_cache_active_set_unlocked(void)
{
return sched_cache_active_set(false);
}
+
+/*
+ * Update the bottom sched_domain's llc_bytes for @cpu and all its
+ * LLC siblings. Called from cacheinfo_cpu_online() or
+ * cacheinfo_cpu_pre_down() with cpu hotplug lock held.
+ *
+ * Note: get_effective_llc_bytes() returns 0 on PowerPC.
+ * thus cache aware scheduling is disabled on PowerPC for
+ * now. PowerPC does not use the generic cacheinfo framework --
+ * it has its own cacheinfo with a separate struct cache hierarchy
+ * and does not populates the per-CPU struct cpu_cacheinfo array
+ * that get_cpu_cacheinfo_llc() reads.
+ */
+void sched_update_llc_bytes(unsigned int cpu)
+{
+ struct sched_domain *sd, *sdp;
+ unsigned int i;
+
+ sched_domains_mutex_lock();
+
+ sdp = rcu_dereference_sched_domain(per_cpu(sd_llc, cpu));
+ if (!sdp)
+ goto unlock;
+
+ /*
+ * ci->shared_cpu_map is built incrementally as CPUs come
+ * online, so the first CPU in an LLC initially sees
+ * hw_weight == 1 and computes an inflated llc_bytes in
+ * get_effective_llc_bytes(). Re-evaluating every LLC
+ * sibling on each online event corrects this once the full
+ * shared_cpu_map is known.
+ */
+ for_each_cpu(i, sched_domain_span(sdp)) {
+ sd = rcu_dereference_sched_domain(cpu_rq(i)->sd);
+ if (sd)
+ sd->llc_bytes = get_effective_llc_bytes(i, sdp);
+ }
+
+unlock:
+ sched_domains_mutex_unlock();
+}
#else
static bool alloc_sd_llc(const struct cpumask *cpu_map,
struct s_data *d)
© 2016 - 2026 Red Hat, Inc.