[PATCH v3 09/33] target/ppc/mmu_common.c: Introduce mmu6xx_get_physical_address()

BALATON Zoltan posted 33 patches 6 months, 3 weeks ago
Maintainers: BALATON Zoltan <balaton@eik.bme.hu>, Nicholas Piggin <npiggin@gmail.com>, Daniel Henrique Barboza <danielhb413@gmail.com>
There is a newer version of this series
[PATCH v3 09/33] target/ppc/mmu_common.c: Introduce mmu6xx_get_physical_address()
Posted by BALATON Zoltan 6 months, 3 weeks ago
Repurpose get_segment_6xx_tlb() to do the whole address translation
for POWERPC_MMU_SOFT_6xx MMU model by moving the BAT check there and
renaming it to match other similar functions. These are only called
once together so no need to keep these separate functions and
combining them simplifies the caller allowing further restructuring.

Signed-off-by: BALATON Zoltan <balaton@eik.bme.hu>
---
 target/ppc/mmu_common.c | 26 ++++++++++++--------------
 1 file changed, 12 insertions(+), 14 deletions(-)

diff --git a/target/ppc/mmu_common.c b/target/ppc/mmu_common.c
index aa137123a4..181273579b 100644
--- a/target/ppc/mmu_common.c
+++ b/target/ppc/mmu_common.c
@@ -360,19 +360,23 @@ static int get_bat_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
     return ret;
 }
 
-/* Perform segment based translation */
-static int get_segment_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
-                               target_ulong eaddr, MMUAccessType access_type,
-                               int type)
+static int mmu6xx_get_physical_address(CPUPPCState *env, mmu_ctx_t *ctx,
+                                       target_ulong eaddr,
+                                       MMUAccessType access_type, int type)
 {
     PowerPCCPU *cpu = env_archcpu(env);
     hwaddr hash;
-    target_ulong vsid;
+    target_ulong vsid, sr, pgidx;
     int ds, target_page_bits;
     bool pr;
     int ret;
-    target_ulong sr, pgidx;
 
+    /* First try to find a BAT entry if there are any */
+    if (env->nb_BATs && get_bat_6xx_tlb(env, ctx, eaddr, access_type) == 0) {
+        return 0;
+    }
+
+    /* Perform segment based translation when no BATs matched */
     pr = FIELD_EX64(env->msr, MSR, PR);
     ctx->eaddr = eaddr;
 
@@ -1194,14 +1198,8 @@ int get_physical_address_wtlb(CPUPPCState *env, mmu_ctx_t *ctx,
         if (real_mode) {
             ret = check_physical(env, ctx, eaddr, access_type);
         } else {
-            /* Try to find a BAT */
-            if (env->nb_BATs != 0) {
-                ret = get_bat_6xx_tlb(env, ctx, eaddr, access_type);
-            }
-            if (ret < 0) {
-                /* We didn't match any BAT entry or don't have BATs */
-                ret = get_segment_6xx_tlb(env, ctx, eaddr, access_type, type);
-            }
+            ret = mmu6xx_get_physical_address(env, ctx, eaddr, access_type,
+                                              type);
         }
         break;
 
-- 
2.30.9
Re: [PATCH v3 09/33] target/ppc/mmu_common.c: Introduce mmu6xx_get_physical_address()
Posted by Nicholas Piggin 6 months, 2 weeks ago
On Wed May 8, 2024 at 10:15 AM AEST, BALATON Zoltan wrote:
> Repurpose get_segment_6xx_tlb() to do the whole address translation
> for POWERPC_MMU_SOFT_6xx MMU model by moving the BAT check there and
> renaming it to match other similar functions. These are only called
> once together so no need to keep these separate functions and
> combining them simplifies the caller allowing further restructuring.
>

Reviewed-by: Nicholas Piggin <npiggin@gmail.com>

> Signed-off-by: BALATON Zoltan <balaton@eik.bme.hu>
> ---
>  target/ppc/mmu_common.c | 26 ++++++++++++--------------
>  1 file changed, 12 insertions(+), 14 deletions(-)
>
> diff --git a/target/ppc/mmu_common.c b/target/ppc/mmu_common.c
> index aa137123a4..181273579b 100644
> --- a/target/ppc/mmu_common.c
> +++ b/target/ppc/mmu_common.c
> @@ -360,19 +360,23 @@ static int get_bat_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
>      return ret;
>  }
>  
> -/* Perform segment based translation */
> -static int get_segment_6xx_tlb(CPUPPCState *env, mmu_ctx_t *ctx,
> -                               target_ulong eaddr, MMUAccessType access_type,
> -                               int type)
> +static int mmu6xx_get_physical_address(CPUPPCState *env, mmu_ctx_t *ctx,
> +                                       target_ulong eaddr,
> +                                       MMUAccessType access_type, int type)
>  {
>      PowerPCCPU *cpu = env_archcpu(env);
>      hwaddr hash;
> -    target_ulong vsid;
> +    target_ulong vsid, sr, pgidx;
>      int ds, target_page_bits;
>      bool pr;
>      int ret;
> -    target_ulong sr, pgidx;
>  
> +    /* First try to find a BAT entry if there are any */
> +    if (env->nb_BATs && get_bat_6xx_tlb(env, ctx, eaddr, access_type) == 0) {
> +        return 0;
> +    }
> +
> +    /* Perform segment based translation when no BATs matched */
>      pr = FIELD_EX64(env->msr, MSR, PR);
>      ctx->eaddr = eaddr;
>  
> @@ -1194,14 +1198,8 @@ int get_physical_address_wtlb(CPUPPCState *env, mmu_ctx_t *ctx,
>          if (real_mode) {
>              ret = check_physical(env, ctx, eaddr, access_type);
>          } else {
> -            /* Try to find a BAT */
> -            if (env->nb_BATs != 0) {
> -                ret = get_bat_6xx_tlb(env, ctx, eaddr, access_type);
> -            }
> -            if (ret < 0) {
> -                /* We didn't match any BAT entry or don't have BATs */
> -                ret = get_segment_6xx_tlb(env, ctx, eaddr, access_type, type);
> -            }
> +            ret = mmu6xx_get_physical_address(env, ctx, eaddr, access_type,
> +                                              type);
>          }
>          break;
>