Match the code in hpet.c; this also allows removing the
BqlCell from the num_timers field.
Reviewed-by: Zhao Liu <zhao1.liu@intel.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
---
rust/hw/timer/hpet/src/device.rs | 16 +++++++---------
rust/hw/timer/hpet/src/fw_cfg.rs | 7 +++----
2 files changed, 10 insertions(+), 13 deletions(-)
diff --git a/rust/hw/timer/hpet/src/device.rs b/rust/hw/timer/hpet/src/device.rs
index a957de1e767..cd439f90b7e 100644
--- a/rust/hw/timer/hpet/src/device.rs
+++ b/rust/hw/timer/hpet/src/device.rs
@@ -725,18 +725,16 @@ fn post_init(&self) {
}
fn realize(&self) -> qemu_api::Result<()> {
+ if self.num_timers.get() < HPET_MIN_TIMERS || self.num_timers.get() > HPET_MAX_TIMERS {
+ Err(format!(
+ "hpet.num_timers must be between {HPET_MIN_TIMERS} and {HPET_MAX_TIMERS}"
+ ))?;
+ }
if self.int_route_cap == 0 {
- // TODO: Add error binding: warn_report()
- println!("Hpet's hpet-intcap property not initialized");
+ Err("hpet.hpet-intcap property not initialized")?;
}
- self.hpet_id.set(HPETFwConfig::assign_hpet_id());
-
- if self.num_timers.get() < HPET_MIN_TIMERS {
- self.num_timers.set(HPET_MIN_TIMERS);
- } else if self.num_timers.get() > HPET_MAX_TIMERS {
- self.num_timers.set(HPET_MAX_TIMERS);
- }
+ self.hpet_id.set(HPETFwConfig::assign_hpet_id()?);
self.init_timer();
// 64-bit General Capabilities and ID Register; LegacyReplacementRoute.
diff --git a/rust/hw/timer/hpet/src/fw_cfg.rs b/rust/hw/timer/hpet/src/fw_cfg.rs
index 6c10316104c..619d662ee1e 100644
--- a/rust/hw/timer/hpet/src/fw_cfg.rs
+++ b/rust/hw/timer/hpet/src/fw_cfg.rs
@@ -36,7 +36,7 @@ unsafe impl Zeroable for HPETFwConfig {}
};
impl HPETFwConfig {
- pub(crate) fn assign_hpet_id() -> usize {
+ pub(crate) fn assign_hpet_id() -> Result<usize, &'static str> {
assert!(bql_locked());
// SAFETY: all accesses go through these methods, which guarantee
// that the accesses are protected by the BQL.
@@ -48,13 +48,12 @@ pub(crate) fn assign_hpet_id() -> usize {
}
if fw_cfg.count == 8 {
- // TODO: Add error binding: error_setg()
- panic!("Only 8 instances of HPET is allowed");
+ Err("Only 8 instances of HPET are allowed")?;
}
let id: usize = fw_cfg.count.into();
fw_cfg.count += 1;
- id
+ Ok(id)
}
pub(crate) fn update_hpet_cfg(hpet_id: usize, timer_block_id: u32, address: u64) {
--