[PATCH v2 0/7] vfio/igd: add passthrough support for IGDs of gen 11 and later

Corvin Köhne posted 7 patches 2 months, 3 weeks ago
Only 5 patches received!
There is a newer version of this series
hw/vfio/igd.c        | 185 +++++++++++++++++++++++++++++++++++++------
hw/vfio/pci-quirks.c |   1 +
hw/vfio/pci.h        |   1 +
3 files changed, 161 insertions(+), 26 deletions(-)
[PATCH v2 0/7] vfio/igd: add passthrough support for IGDs of gen 11 and later
Posted by Corvin Köhne 2 months, 3 weeks ago
Hi,

Qemu has experimental support for GPU passthrough of Intels integrated graphic
devices. Unfortunately, Intel has changed some bits for their gen 11 devices
and later. To support these devices, we have to account for those changes. This
patch series adds the missing bits on the Qemu side.

I've tested the patch series on an ElkhartLake and TigerLake device. On the
guest side, I've tested an EFI environment (GOP driver), a Linux guest and a
Windows VM. The driver of all guests are able to use the GPU and produce an
output on the connected display.

Corvin Köhne (7):
  vfio/igd: return an invalid generation for unknown devices
  vfio/igd: support legacy mode for all known generations
  vfio/igd: use new BDSM register location and size for gen 11 and later
  vfio/igd: add new bar0 quirk to emulate BDSM mirror
  vfio/igd: add ID's for ElkhartLake and TigerLake
  vfio/igd: don't set stolen memory size to zero
  vfio/igd: correctly calculate stolen memory size for gen 9 and later

 hw/vfio/igd.c        | 185 +++++++++++++++++++++++++++++++++++++------
 hw/vfio/pci-quirks.c |   1 +
 hw/vfio/pci.h        |   1 +
 3 files changed, 161 insertions(+), 26 deletions(-)

-- 
2.46.0

This email contains confidential information. If you have received it in error, you must not read, use, copy or pass on this e-mail or its attachments. If you have received the e-mail in error, please inform me immediately by reply e-mail and then delete this e-mail from your system. Thank you
 
Diese E-Mail enthält vertrauliche Informationen. Sollten Sie sie irrtümlich erhalten haben, dürfen Sie diese E-Mail oder ihre Anhänge nicht lesen, verwenden, kopieren oder weitergeben. Sollten Sie die Mail versehentlich erhalten haben, teilen Sie mir dies bitte umgehend per Antwort-E-Mail mit und löschen Sie diese E-Mail dann aus Ihrem System. Vielen Dank

Beckhoff Automation GmbH & Co. KG | Managing Director: Dipl. Phys. Hans Beckhoff
Registered office: Verl, Germany | Register court: Guetersloh HRA 7075