[PATCH 2/7] vfio/igd: support legacy mode for all known generations

Corvin Köhne posted 7 patches 3 months ago
There is a newer version of this series
[PATCH 2/7] vfio/igd: support legacy mode for all known generations
Posted by Corvin Köhne 3 months ago
We're soon going to add support for legacy mode to ElkhartLake and
TigerLake devices. Those are gen 11 and 12 devices. At the moment, all
devices identified by our igd_gen function do support legacy mode. This
won't change when adding our new devices of gen 11 and 12. Therefore, it
makes more sense to accept legacy mode for all known devices instead of
maintaining a long list of known good generations. If we add a new
generation to igd_gen which doesn't support legacy mode for some reason,
it'll be easy to advance the check to reject legacy mode for this
specific generation.

Signed-off-by: Corvin Köhne <c.koehne@beckhoff.com>
---
 hw/vfio/igd.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/hw/vfio/igd.c b/hw/vfio/igd.c
index 650a323dda..d5e57656a8 100644
--- a/hw/vfio/igd.c
+++ b/hw/vfio/igd.c
@@ -416,7 +416,7 @@ void vfio_probe_igd_bar4_quirk(VFIOPCIDevice *vdev, int nr)
      * devices maintain compatibility with generation 8.
      */
     gen = igd_gen(vdev);
-    if (gen != 6 && gen != 8) {
+    if (gen == -1) {
         error_report("IGD device %s is unsupported in legacy mode, "
                      "try SandyBridge or newer", vdev->vbasedev.name);
         return;
-- 
2.46.0

This email contains confidential information. If you have received it in error, you must not read, use, copy or pass on this e-mail or its attachments. If you have received the e-mail in error, please inform me immediately by reply e-mail and then delete this e-mail from your system. Thank you
 
Diese E-Mail enthält vertrauliche Informationen. Sollten Sie sie irrtümlich erhalten haben, dürfen Sie diese E-Mail oder ihre Anhänge nicht lesen, verwenden, kopieren oder weitergeben. Sollten Sie die Mail versehentlich erhalten haben, teilen Sie mir dies bitte umgehend per Antwort-E-Mail mit und löschen Sie diese E-Mail dann aus Ihrem System. Vielen Dank