We can turn logging on/off globally instead of per-function.
Remove use_log from run_job, and use python logging to turn on
diffable output when we run through a script entry point.
(No, I have no idea why output on 245 changed. I really don't.)
Signed-off-by: John Snow <jsnow@redhat.com>
---
tests/qemu-iotests/030 | 4 +--
tests/qemu-iotests/245 | 1 +
tests/qemu-iotests/245.out | 24 +++++++++---------
tests/qemu-iotests/iotests.py | 48 ++++++++++++++++++++---------------
4 files changed, 43 insertions(+), 34 deletions(-)
diff --git a/tests/qemu-iotests/030 b/tests/qemu-iotests/030
index 1b69f318c6..a382cb430b 100755
--- a/tests/qemu-iotests/030
+++ b/tests/qemu-iotests/030
@@ -411,8 +411,8 @@ class TestParallelOps(iotests.QMPTestCase):
result = self.vm.qmp('block-job-set-speed', device='drive0', speed=0)
self.assert_qmp(result, 'return', {})
- self.vm.run_job(job='drive0', auto_dismiss=True, use_log=False)
- self.vm.run_job(job='node4', auto_dismiss=True, use_log=False)
+ self.vm.run_job(job='drive0', auto_dismiss=True)
+ self.vm.run_job(job='node4', auto_dismiss=True)
self.assert_no_active_block_jobs()
# Test a block-stream and a block-commit job in parallel
diff --git a/tests/qemu-iotests/245 b/tests/qemu-iotests/245
index bc1ceb9792..3bc29acb33 100644
--- a/tests/qemu-iotests/245
+++ b/tests/qemu-iotests/245
@@ -1000,4 +1000,5 @@ class TestBlockdevReopen(iotests.QMPTestCase):
self.reopen(opts, {'backing': 'hd2'})
if __name__ == '__main__':
+ iotests.activate_logging()
iotests.main(supported_fmts=["qcow2"])
diff --git a/tests/qemu-iotests/245.out b/tests/qemu-iotests/245.out
index a19de5214d..15c3630e92 100644
--- a/tests/qemu-iotests/245.out
+++ b/tests/qemu-iotests/245.out
@@ -1,17 +1,17 @@
+{"execute": "job-finalize", "arguments": {"id": "commit0"}}
+{"return": {}}
+{"data": {"id": "commit0", "type": "commit"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
+{"data": {"device": "commit0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "commit"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
+{"execute": "job-finalize", "arguments": {"id": "stream0"}}
+{"return": {}}
+{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
+{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
+{"execute": "job-finalize", "arguments": {"id": "stream0"}}
+{"return": {}}
+{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
+{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
..................
----------------------------------------------------------------------
Ran 18 tests
OK
-{"execute": "job-finalize", "arguments": {"id": "commit0"}}
-{"return": {}}
-{"data": {"id": "commit0", "type": "commit"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
-{"data": {"device": "commit0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "commit"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
-{"execute": "job-finalize", "arguments": {"id": "stream0"}}
-{"return": {}}
-{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
-{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
-{"execute": "job-finalize", "arguments": {"id": "stream0"}}
-{"return": {}}
-{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
-{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
diff --git a/tests/qemu-iotests/iotests.py b/tests/qemu-iotests/iotests.py
index 5e9b2989dd..d55ca864eb 100644
--- a/tests/qemu-iotests/iotests.py
+++ b/tests/qemu-iotests/iotests.py
@@ -35,6 +35,13 @@ from collections import OrderedDict
sys.path.append(os.path.join(os.path.dirname(__file__), '..', '..', 'python'))
from qemu import qtest
+# Use this logger for logging messages directly from the iotests module
+logger = logging.getLogger(__name__)
+logger.addHandler(logging.NullHandler())
+
+# Use this logger for messages that ought to be used for diff output.
+test_logger = logging.getLogger('.'.join((__name__, 'iotest')))
+test_logger.addHandler(logging.NullHandler())
# This will not work if arguments contain spaces but is necessary if we
# want to support the override options that ./check supports.
@@ -343,10 +350,10 @@ def log(msg, filters=[], indent=None):
separators = (', ', ': ') if indent is None else (',', ': ')
# Don't sort if it's already sorted
do_sort = not isinstance(msg, OrderedDict)
- print(json.dumps(msg, sort_keys=do_sort,
- indent=indent, separators=separators))
+ test_logger.info(json.dumps(msg, sort_keys=do_sort,
+ indent=indent, separators=separators))
else:
- print(msg)
+ test_logger.info(msg)
class Timeout:
def __init__(self, seconds, errmsg = "Timeout"):
@@ -559,7 +566,7 @@ class VM(qtest.QEMUQtestMachine):
# Returns None on success, and an error string on failure
def run_job(self, job, auto_finalize=True, auto_dismiss=False,
- pre_finalize=None, cancel=False, use_log=True, wait=60.0):
+ pre_finalize=None, cancel=False, wait=60.0):
"""
run_job moves a job from creation through to dismissal.
@@ -572,7 +579,6 @@ class VM(qtest.QEMUQtestMachine):
invoked prior to issuing job-finalize, if any.
:param cancel: Bool. When true, cancels the job after the pre_finalize
callback.
- :param use_log: Bool. When false, does not log QMP messages.
:param wait: Float. Timeout value specifying how long to wait for any
event, in seconds. Defaults to 60.0.
"""
@@ -590,8 +596,7 @@ class VM(qtest.QEMUQtestMachine):
while True:
ev = filter_qmp_event(self.events_wait(events))
if ev['event'] != 'JOB_STATUS_CHANGE':
- if use_log:
- log(ev)
+ log(ev)
continue
status = ev['data']['status']
if status == 'aborting':
@@ -599,24 +604,15 @@ class VM(qtest.QEMUQtestMachine):
for j in result['return']:
if j['id'] == job:
error = j['error']
- if use_log:
- log('Job failed: %s' % (j['error']))
+ log('Job failed: %s' % (j['error']))
elif status == 'pending' and not auto_finalize:
if pre_finalize:
pre_finalize()
- if cancel and use_log:
+ if cancel:
self.qmp_log('job-cancel', id=job)
- elif cancel:
- self.qmp('job-cancel', id=job)
- if use_log:
- self.qmp_log('job-finalize', id=job)
- else:
- self.qmp('job-finalize', id=job)
+ self.qmp_log('job-finalize', id=job)
elif status == 'concluded' and not auto_dismiss:
- if use_log:
- self.qmp_log('job-dismiss', id=job)
- else:
- self.qmp('job-dismiss', id=job)
+ self.qmp_log('job-dismiss', id=job)
elif status == 'null':
return error
@@ -924,6 +920,7 @@ def execute_setup_common(supported_fmts=[], supported_oses=['linux'],
output = io.BytesIO()
logging.basicConfig(level=(logging.DEBUG if debug else logging.WARN))
+ logger.debug("iotests debugging messages active")
return output, verbosity, debug
def execute_test(test_function=None, *args, **kwargs):
@@ -935,14 +932,25 @@ def execute_test(test_function=None, *args, **kwargs):
else:
test_function()
+def activate_logging():
+ """Activate iotests.log() output to stdout for script-style tests."""
+ handler = logging.StreamHandler(stream=sys.stdout)
+ formatter = logging.Formatter('%(message)s')
+ handler.setFormatter(formatter)
+ test_logger.addHandler(handler)
+ test_logger.setLevel(logging.INFO)
+ test_logger.propagate = False
+
# This is called from script-style iotests without a single point of entry
def script_initialize(*args, **kwargs):
"""Initialize script-style tests without running any tests."""
+ activate_logging()
execute_setup_common(*args, **kwargs)
# This is called from script-style iotests with a single point of entry
def script_main(test_function, *args, **kwargs):
"""Run script-style tests outside of the unittest framework"""
+ activate_logging()
execute_test(test_function, *args, **kwargs)
# This is called from unittest style iotests
--
2.21.0
On Fri, Jul 26, 2019 at 06:52:01PM -0400, John Snow wrote:
> We can turn logging on/off globally instead of per-function.
>
> Remove use_log from run_job, and use python logging to turn on
> diffable output when we run through a script entry point.
>
> (No, I have no idea why output on 245 changed. I really don't.)
I believe this happens because the logging StreamHandler will
flush the stream at every call.
I see the same output reordering on 245 if I add a
sys.stdout.flush() call to iotests.log(), or if I change
iotests.main() to use sys.stdout for the unittest runner output.
>
> Signed-off-by: John Snow <jsnow@redhat.com>
> ---
> tests/qemu-iotests/030 | 4 +--
> tests/qemu-iotests/245 | 1 +
> tests/qemu-iotests/245.out | 24 +++++++++---------
> tests/qemu-iotests/iotests.py | 48 ++++++++++++++++++++---------------
> 4 files changed, 43 insertions(+), 34 deletions(-)
>
> diff --git a/tests/qemu-iotests/030 b/tests/qemu-iotests/030
> index 1b69f318c6..a382cb430b 100755
> --- a/tests/qemu-iotests/030
> +++ b/tests/qemu-iotests/030
> @@ -411,8 +411,8 @@ class TestParallelOps(iotests.QMPTestCase):
> result = self.vm.qmp('block-job-set-speed', device='drive0', speed=0)
> self.assert_qmp(result, 'return', {})
>
> - self.vm.run_job(job='drive0', auto_dismiss=True, use_log=False)
> - self.vm.run_job(job='node4', auto_dismiss=True, use_log=False)
> + self.vm.run_job(job='drive0', auto_dismiss=True)
> + self.vm.run_job(job='node4', auto_dismiss=True)
So, this one is the only run_job() caller specifying
use_log=False. It doesn't call activate_logging() anywhere, so
it seems OK.
However, we need to ensure all the other run_job() callers will
actually enable logging. The remaining run_job() callers are:
206 207 210 211 212 213 237 245 255 256.
These look OK:
206:iotests.script_initialize(supported_fmts=['qcow2'])
245: iotests.activate_logging()
255:iotests.script_initialize(supported_fmts=['qcow2'])
256:iotests.script_initialize(supported_fmts=['qcow2'])
257: iotests.script_main(main, supported_fmts=['qcow2'])
These don't seem to call activate_logging() anywhere:
207 210 211 212 213 237.
What about other scripts calling log() that aren't calling activate_logging()?
Let's see:
$ git grep -LE 'script_main|script_initialize|activate_logging' \
$(grep -lP '(?<!get_)log\(' [0-9]*)
207
210
211
212
213
237
$
I didn't run all of these test cases, but I can see that 210 is
now failing:
$ ./check -luks 210
QEMU -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../x86_64-softmmu/qemu-system-x86_64" -nodefaults -machine accel=qtest
QEMU_IMG -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../qemu-img"
QEMU_IO -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../qemu-io" --cache writeback
QEMU_NBD -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../qemu-nbd"
IMGFMT -- luks (iter-time=10)
IMGPROTO -- file
TEST_DIR -- /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/scratch
SOCKET_SCM_HELPER -- /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/socket_scm_helper
210 fail [20:20:37] [20:21:00] (last: 22s) output mismatch (see 210.out.bad)
--- /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/210.out 2019-07-28 18:38:18.040555415 -0300
+++ /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/210.out.bad 2019-07-28 20:20:37.398971280 -0300
@@ -1,231 +0,0 @@
-=== Successful image creation (defaults) ===
-
-{"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"driver": "file", "filename": "TEST_DIR/PID-t.luks", "size": 0}}}
[...]
As most test cases require logging to be enabled, my suggestion
is to activate logging by default and provide a
disable_test_logging() function that can be used by 030.
> self.assert_no_active_block_jobs()
>
> # Test a block-stream and a block-commit job in parallel
> diff --git a/tests/qemu-iotests/245 b/tests/qemu-iotests/245
> index bc1ceb9792..3bc29acb33 100644
> --- a/tests/qemu-iotests/245
> +++ b/tests/qemu-iotests/245
> @@ -1000,4 +1000,5 @@ class TestBlockdevReopen(iotests.QMPTestCase):
> self.reopen(opts, {'backing': 'hd2'})
>
> if __name__ == '__main__':
> + iotests.activate_logging()
> iotests.main(supported_fmts=["qcow2"])
> diff --git a/tests/qemu-iotests/245.out b/tests/qemu-iotests/245.out
> index a19de5214d..15c3630e92 100644
> --- a/tests/qemu-iotests/245.out
> +++ b/tests/qemu-iotests/245.out
> @@ -1,17 +1,17 @@
> +{"execute": "job-finalize", "arguments": {"id": "commit0"}}
> +{"return": {}}
> +{"data": {"id": "commit0", "type": "commit"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> +{"data": {"device": "commit0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "commit"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> +{"execute": "job-finalize", "arguments": {"id": "stream0"}}
> +{"return": {}}
> +{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> +{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> +{"execute": "job-finalize", "arguments": {"id": "stream0"}}
> +{"return": {}}
> +{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> +{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> ..................
> ----------------------------------------------------------------------
> Ran 18 tests
>
> OK
> -{"execute": "job-finalize", "arguments": {"id": "commit0"}}
> -{"return": {}}
> -{"data": {"id": "commit0", "type": "commit"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> -{"data": {"device": "commit0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "commit"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> -{"execute": "job-finalize", "arguments": {"id": "stream0"}}
> -{"return": {}}
> -{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> -{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> -{"execute": "job-finalize", "arguments": {"id": "stream0"}}
> -{"return": {}}
> -{"data": {"id": "stream0", "type": "stream"}, "event": "BLOCK_JOB_PENDING", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> -{"data": {"device": "stream0", "len": 3145728, "offset": 3145728, "speed": 0, "type": "stream"}, "event": "BLOCK_JOB_COMPLETED", "timestamp": {"microseconds": "USECS", "seconds": "SECS"}}
> diff --git a/tests/qemu-iotests/iotests.py b/tests/qemu-iotests/iotests.py
> index 5e9b2989dd..d55ca864eb 100644
> --- a/tests/qemu-iotests/iotests.py
> +++ b/tests/qemu-iotests/iotests.py
> @@ -35,6 +35,13 @@ from collections import OrderedDict
> sys.path.append(os.path.join(os.path.dirname(__file__), '..', '..', 'python'))
> from qemu import qtest
>
> +# Use this logger for logging messages directly from the iotests module
> +logger = logging.getLogger(__name__)
> +logger.addHandler(logging.NullHandler())
> +
> +# Use this logger for messages that ought to be used for diff output.
> +test_logger = logging.getLogger('.'.join((__name__, 'iotest')))
> +test_logger.addHandler(logging.NullHandler())
>
> # This will not work if arguments contain spaces but is necessary if we
> # want to support the override options that ./check supports.
> @@ -343,10 +350,10 @@ def log(msg, filters=[], indent=None):
> separators = (', ', ': ') if indent is None else (',', ': ')
> # Don't sort if it's already sorted
> do_sort = not isinstance(msg, OrderedDict)
> - print(json.dumps(msg, sort_keys=do_sort,
> - indent=indent, separators=separators))
> + test_logger.info(json.dumps(msg, sort_keys=do_sort,
> + indent=indent, separators=separators))
> else:
> - print(msg)
> + test_logger.info(msg)
>
> class Timeout:
> def __init__(self, seconds, errmsg = "Timeout"):
> @@ -559,7 +566,7 @@ class VM(qtest.QEMUQtestMachine):
>
> # Returns None on success, and an error string on failure
> def run_job(self, job, auto_finalize=True, auto_dismiss=False,
> - pre_finalize=None, cancel=False, use_log=True, wait=60.0):
> + pre_finalize=None, cancel=False, wait=60.0):
> """
> run_job moves a job from creation through to dismissal.
>
> @@ -572,7 +579,6 @@ class VM(qtest.QEMUQtestMachine):
> invoked prior to issuing job-finalize, if any.
> :param cancel: Bool. When true, cancels the job after the pre_finalize
> callback.
> - :param use_log: Bool. When false, does not log QMP messages.
> :param wait: Float. Timeout value specifying how long to wait for any
> event, in seconds. Defaults to 60.0.
> """
> @@ -590,8 +596,7 @@ class VM(qtest.QEMUQtestMachine):
> while True:
> ev = filter_qmp_event(self.events_wait(events))
> if ev['event'] != 'JOB_STATUS_CHANGE':
> - if use_log:
> - log(ev)
> + log(ev)
> continue
> status = ev['data']['status']
> if status == 'aborting':
> @@ -599,24 +604,15 @@ class VM(qtest.QEMUQtestMachine):
> for j in result['return']:
> if j['id'] == job:
> error = j['error']
> - if use_log:
> - log('Job failed: %s' % (j['error']))
> + log('Job failed: %s' % (j['error']))
> elif status == 'pending' and not auto_finalize:
> if pre_finalize:
> pre_finalize()
> - if cancel and use_log:
> + if cancel:
> self.qmp_log('job-cancel', id=job)
> - elif cancel:
> - self.qmp('job-cancel', id=job)
> - if use_log:
> - self.qmp_log('job-finalize', id=job)
> - else:
> - self.qmp('job-finalize', id=job)
> + self.qmp_log('job-finalize', id=job)
> elif status == 'concluded' and not auto_dismiss:
> - if use_log:
> - self.qmp_log('job-dismiss', id=job)
> - else:
> - self.qmp('job-dismiss', id=job)
> + self.qmp_log('job-dismiss', id=job)
> elif status == 'null':
> return error
>
> @@ -924,6 +920,7 @@ def execute_setup_common(supported_fmts=[], supported_oses=['linux'],
> output = io.BytesIO()
>
> logging.basicConfig(level=(logging.DEBUG if debug else logging.WARN))
> + logger.debug("iotests debugging messages active")
> return output, verbosity, debug
>
> def execute_test(test_function=None, *args, **kwargs):
> @@ -935,14 +932,25 @@ def execute_test(test_function=None, *args, **kwargs):
> else:
> test_function()
>
> +def activate_logging():
> + """Activate iotests.log() output to stdout for script-style tests."""
> + handler = logging.StreamHandler(stream=sys.stdout)
> + formatter = logging.Formatter('%(message)s')
> + handler.setFormatter(formatter)
> + test_logger.addHandler(handler)
> + test_logger.setLevel(logging.INFO)
> + test_logger.propagate = False
> +
> # This is called from script-style iotests without a single point of entry
> def script_initialize(*args, **kwargs):
> """Initialize script-style tests without running any tests."""
> + activate_logging()
> execute_setup_common(*args, **kwargs)
>
> # This is called from script-style iotests with a single point of entry
> def script_main(test_function, *args, **kwargs):
> """Run script-style tests outside of the unittest framework"""
> + activate_logging()
> execute_test(test_function, *args, **kwargs)
>
> # This is called from unittest style iotests
> --
> 2.21.0
>
--
Eduardo
On 7/28/19 7:36 PM, Eduardo Habkost wrote:
> On Fri, Jul 26, 2019 at 06:52:01PM -0400, John Snow wrote:
>> We can turn logging on/off globally instead of per-function.
>>
>> Remove use_log from run_job, and use python logging to turn on
>> diffable output when we run through a script entry point.
>>
>> (No, I have no idea why output on 245 changed. I really don't.)
>
> I believe this happens because the logging StreamHandler will
> flush the stream at every call.
>
I'm surprised print doesn't flush that often.
> I see the same output reordering on 245 if I add a
> sys.stdout.flush() call to iotests.log(), or if I change
> iotests.main() to use sys.stdout for the unittest runner output.
>
>>
>> Signed-off-by: John Snow <jsnow@redhat.com>
>> ---
>> tests/qemu-iotests/030 | 4 +--
>> tests/qemu-iotests/245 | 1 +
>> tests/qemu-iotests/245.out | 24 +++++++++---------
>> tests/qemu-iotests/iotests.py | 48 ++++++++++++++++++++---------------
>> 4 files changed, 43 insertions(+), 34 deletions(-)
>>
>> diff --git a/tests/qemu-iotests/030 b/tests/qemu-iotests/030
>> index 1b69f318c6..a382cb430b 100755
>> --- a/tests/qemu-iotests/030
>> +++ b/tests/qemu-iotests/030
>> @@ -411,8 +411,8 @@ class TestParallelOps(iotests.QMPTestCase):
>> result = self.vm.qmp('block-job-set-speed', device='drive0', speed=0)
>> self.assert_qmp(result, 'return', {})
>>
>> - self.vm.run_job(job='drive0', auto_dismiss=True, use_log=False)
>> - self.vm.run_job(job='node4', auto_dismiss=True, use_log=False)
>> + self.vm.run_job(job='drive0', auto_dismiss=True)
>> + self.vm.run_job(job='node4', auto_dismiss=True)
>
> So, this one is the only run_job() caller specifying
> use_log=False. It doesn't call activate_logging() anywhere, so
> it seems OK.
>
Yah
> However, we need to ensure all the other run_job() callers will
> actually enable logging. The remaining run_job() callers are:
> 206 207 210 211 212 213 237 245 255 256.
>
> These look OK:
> 206:iotests.script_initialize(supported_fmts=['qcow2'])
> 245: iotests.activate_logging()
> 255:iotests.script_initialize(supported_fmts=['qcow2'])
> 256:iotests.script_initialize(supported_fmts=['qcow2'])
> 257: iotests.script_main(main, supported_fmts=['qcow2'])
>
> These don't seem to call activate_logging() anywhere:
> 207 210 211 212 213 237.
>
There's the quick hack -- not verifying all the non-qcow tests as per usual.
All of these are script-style and should call to script_initialize now
instead. Fixed!
> What about other scripts calling log() that aren't calling activate_logging()?
> Let's see:
>
> $ git grep -LE 'script_main|script_initialize|activate_logging' \
> $(grep -lP '(?<!get_)log\(' [0-9]*)
> 207
> 210
> 211
> 212
> 213
> 237
> $
>
>
> I didn't run all of these test cases, but I can see that 210 is
> now failing:
>
> $ ./check -luks 210
> QEMU -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../x86_64-softmmu/qemu-system-x86_64" -nodefaults -machine accel=qtest
> QEMU_IMG -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../qemu-img"
> QEMU_IO -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../qemu-io" --cache writeback
> QEMU_NBD -- "/home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/../../qemu-nbd"
> IMGFMT -- luks (iter-time=10)
> IMGPROTO -- file
>
> TEST_DIR -- /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/scratch
> SOCKET_SCM_HELPER -- /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/socket_scm_helper
>
> 210 fail [20:20:37] [20:21:00] (last: 22s) output mismatch (see 210.out.bad)
> --- /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/210.out 2019-07-28 18:38:18.040555415 -0300
> +++ /home/ehabkost/rh/proj/virt/qemu/tests/qemu-iotests/210.out.bad 2019-07-28 20:20:37.398971280 -0300
> @@ -1,231 +0,0 @@
> -=== Successful image creation (defaults) ===
> -
> -{"execute": "blockdev-create", "arguments": {"job-id": "job0", "options": {"driver": "file", "filename": "TEST_DIR/PID-t.luks", "size": 0}}}
> [...]
>
>
> As most test cases require logging to be enabled, my suggestion
> is to activate logging by default and provide a
> disable_test_logging() function that can be used by 030.
>
Actually, we'd need to disable logging for all the unittest style tests,
so it's probably a wash as to whether we do enable-or-disable by
default. I think disable-by-default has the benefit of making it obvious
when you're missing a call to script_initialize, so I'd like to go that
route.
So basically you have:
A) Unittest - disabled by default
B) script-style - enabled by default
You only need to override this layout for one case -- test 245 -- which
was written to expect run_job logging, which I did in this patch.
I'll send a V2 that mocks this up.
--js