When closing a connection, make the nbd-fault-injector flush the socket.
Without this, the output is a bit unreliable with Python 3.
Signed-off-by: Max Reitz <mreitz@redhat.com>
---
tests/qemu-iotests/083.out | 9 +++++++++
tests/qemu-iotests/nbd-fault-injector.py | 1 +
2 files changed, 10 insertions(+)
diff --git a/tests/qemu-iotests/083.out b/tests/qemu-iotests/083.out
index be6079d27e..f9af8bb691 100644
--- a/tests/qemu-iotests/083.out
+++ b/tests/qemu-iotests/083.out
@@ -41,6 +41,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
=== Check disconnect after neg2 ===
+Unable to read from socket: Connection reset by peer
Connection closed
read failed: Input/output error
@@ -54,6 +55,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
=== Check disconnect before request ===
+Unable to read from socket: Connection reset by peer
Connection closed
read failed: Input/output error
@@ -116,6 +118,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/
=== Check disconnect after neg-classic ===
+Unable to read from socket: Connection reset by peer
Connection closed
read failed: Input/output error
@@ -161,6 +164,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock
=== Check disconnect after neg2 ===
+Unable to read from socket: Connection reset by peer
+Connection closed
read failed: Input/output error
=== Check disconnect 8 neg2 ===
@@ -173,6 +178,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock
=== Check disconnect before request ===
+Unable to read from socket: Connection reset by peer
+Connection closed
read failed: Input/output error
=== Check disconnect after request ===
@@ -234,6 +241,8 @@ can't open device nbd+unix:///?socket=TEST_DIR/nbd.sock
=== Check disconnect after neg-classic ===
+Unable to read from socket: Connection reset by peer
+Connection closed
read failed: Input/output error
*** done
diff --git a/tests/qemu-iotests/nbd-fault-injector.py b/tests/qemu-iotests/nbd-fault-injector.py
index f9193c0fae..439a090eb6 100755
--- a/tests/qemu-iotests/nbd-fault-injector.py
+++ b/tests/qemu-iotests/nbd-fault-injector.py
@@ -112,6 +112,7 @@ class FaultInjectionSocket(object):
if rule.match(event, io):
if rule.when == 0 or bufsize is None:
print('Closing connection on rule match %s' % rule.name)
+ self.sock.flush()
sys.exit(0)
if rule.when != -1:
return rule.when
--
2.17.1
On Mon, Oct 15, 2018 at 04:14:45PM +0200, Max Reitz wrote: > When closing a connection, make the nbd-fault-injector flush the socket. > Without this, the output is a bit unreliable with Python 3. > > Signed-off-by: Max Reitz <mreitz@redhat.com> Reviewed-by: Eduardo Habkost <ehabkost@redhat.com> -- Eduardo
On 10/15/18 10:14 AM, Max Reitz wrote: > When closing a connection, make the nbd-fault-injector flush the socket. > Without this, the output is a bit unreliable with Python 3. > > Signed-off-by: Max Reitz <mreitz@redhat.com> Reviewed-by: Cleber Rosa <crosa@redhat.com>
On 10/15/18 9:14 AM, Max Reitz wrote:
> When closing a connection, make the nbd-fault-injector flush the socket.
> Without this, the output is a bit unreliable with Python 3.
>
> Signed-off-by: Max Reitz <mreitz@redhat.com>
> ---
> tests/qemu-iotests/083.out | 9 +++++++++
> tests/qemu-iotests/nbd-fault-injector.py | 1 +
> 2 files changed, 10 insertions(+)
I already had a complaint that the error message in 083.out should NOT
be printing a message (whether the server is python 2 and auto-flushes,
or python 3 and needs an explicit flush, the message itself is
pointless, and the test is racy as a result). We may need to revisit
this patch when that thread is resolved.
https://lists.gnu.org/archive/html/qemu-devel/2018-08/msg01041.html
That said, I'm not opposed to this patch, if it gets iotests to be more
useful in the meantime.
>
> diff --git a/tests/qemu-iotests/083.out b/tests/qemu-iotests/083.out
> index be6079d27e..f9af8bb691 100644
> --- a/tests/qemu-iotests/083.out
> +++ b/tests/qemu-iotests/083.out
> @@ -41,6 +41,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
>
> === Check disconnect after neg2 ===
>
> +Unable to read from socket: Connection reset by peer
> Connection closed
> read failed: Input/output error
>
> @@ -54,6 +55,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
>
> === Check disconnect before request ===
>
> +Unable to read from socket: Connection reset by peer
> Connection closed
> read failed: Input/output error
>
> @@ -116,6 +118,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/
>
> === Check disconnect after neg-classic ===
>
> +Unable to read from socket: Connection reset by peer
> Connection closed
> read failed: Input/output error
>
> @@ -161,6 +164,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock
>
> === Check disconnect after neg2 ===
>
> +Unable to read from socket: Connection reset by peer
> +Connection closed
> read failed: Input/output error
>
> === Check disconnect 8 neg2 ===
> @@ -173,6 +178,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock
>
> === Check disconnect before request ===
>
> +Unable to read from socket: Connection reset by peer
> +Connection closed
> read failed: Input/output error
>
> === Check disconnect after request ===
> @@ -234,6 +241,8 @@ can't open device nbd+unix:///?socket=TEST_DIR/nbd.sock
>
> === Check disconnect after neg-classic ===
>
> +Unable to read from socket: Connection reset by peer
> +Connection closed
> read failed: Input/output error
>
> *** done
> diff --git a/tests/qemu-iotests/nbd-fault-injector.py b/tests/qemu-iotests/nbd-fault-injector.py
> index f9193c0fae..439a090eb6 100755
> --- a/tests/qemu-iotests/nbd-fault-injector.py
> +++ b/tests/qemu-iotests/nbd-fault-injector.py
> @@ -112,6 +112,7 @@ class FaultInjectionSocket(object):
> if rule.match(event, io):
> if rule.when == 0 or bufsize is None:
> print('Closing connection on rule match %s' % rule.name)
> + self.sock.flush()
> sys.exit(0)
> if rule.when != -1:
> return rule.when
>
--
Eric Blake, Principal Software Engineer
Red Hat, Inc. +1-919-301-3266
Virtualization: qemu.org | libvirt.org
On 16.10.18 20:07, Eric Blake wrote:
> On 10/15/18 9:14 AM, Max Reitz wrote:
>> When closing a connection, make the nbd-fault-injector flush the socket.
>> Without this, the output is a bit unreliable with Python 3.
>>
>> Signed-off-by: Max Reitz <mreitz@redhat.com>
>> ---
>> tests/qemu-iotests/083.out | 9 +++++++++
>> tests/qemu-iotests/nbd-fault-injector.py | 1 +
>> 2 files changed, 10 insertions(+)
>
> I already had a complaint that the error message in 083.out should NOT
> be printing a message
You mean the NBD server itself, right?
> (whether the server is python 2 and auto-flushes,
> or python 3 and needs an explicit flush, the message itself is
> pointless, and the test is racy as a result). We may need to revisit
> this patch when that thread is resolved.
>
> https://lists.gnu.org/archive/html/qemu-devel/2018-08/msg01041.html
Well, it's not like the flush hurts either way. :-)
Max
> That said, I'm not opposed to this patch, if it gets iotests to be more
> useful in the meantime.
>
>>
>> diff --git a/tests/qemu-iotests/083.out b/tests/qemu-iotests/083.out
>> index be6079d27e..f9af8bb691 100644
>> --- a/tests/qemu-iotests/083.out
>> +++ b/tests/qemu-iotests/083.out
>> @@ -41,6 +41,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
>> === Check disconnect after neg2 ===
>> +Unable to read from socket: Connection reset by peer
>> Connection closed
>> read failed: Input/output error
>> @@ -54,6 +55,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo
>> === Check disconnect before request ===
>> +Unable to read from socket: Connection reset by peer
>> Connection closed
>> read failed: Input/output error
>> @@ -116,6 +118,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/
>> === Check disconnect after neg-classic ===
>> +Unable to read from socket: Connection reset by peer
>> Connection closed
>> read failed: Input/output error
>> @@ -161,6 +164,8 @@ can't open device
>> nbd+unix:///foo?socket=TEST_DIR/nbd.sock
>> === Check disconnect after neg2 ===
>> +Unable to read from socket: Connection reset by peer
>> +Connection closed
>> read failed: Input/output error
>> === Check disconnect 8 neg2 ===
>> @@ -173,6 +178,8 @@ can't open device
>> nbd+unix:///foo?socket=TEST_DIR/nbd.sock
>> === Check disconnect before request ===
>> +Unable to read from socket: Connection reset by peer
>> +Connection closed
>> read failed: Input/output error
>> === Check disconnect after request ===
>> @@ -234,6 +241,8 @@ can't open device
>> nbd+unix:///?socket=TEST_DIR/nbd.sock
>> === Check disconnect after neg-classic ===
>> +Unable to read from socket: Connection reset by peer
>> +Connection closed
>> read failed: Input/output error
>> *** done
>> diff --git a/tests/qemu-iotests/nbd-fault-injector.py
>> b/tests/qemu-iotests/nbd-fault-injector.py
>> index f9193c0fae..439a090eb6 100755
>> --- a/tests/qemu-iotests/nbd-fault-injector.py
>> +++ b/tests/qemu-iotests/nbd-fault-injector.py
>> @@ -112,6 +112,7 @@ class FaultInjectionSocket(object):
>> if rule.match(event, io):
>> if rule.when == 0 or bufsize is None:
>> print('Closing connection on rule match %s' %
>> rule.name)
>> + self.sock.flush()
>> sys.exit(0)
>> if rule.when != -1:
>> return rule.when
>>
>
On 10/19/18 4:48 AM, Max Reitz wrote: > On 16.10.18 20:07, Eric Blake wrote: >> On 10/15/18 9:14 AM, Max Reitz wrote: >>> When closing a connection, make the nbd-fault-injector flush the socket. >>> Without this, the output is a bit unreliable with Python 3. >>> >>> Signed-off-by: Max Reitz <mreitz@redhat.com> >>> --- >>> tests/qemu-iotests/083.out | 9 +++++++++ >>> tests/qemu-iotests/nbd-fault-injector.py | 1 + >>> 2 files changed, 10 insertions(+) >> >> I already had a complaint that the error message in 083.out should NOT >> be printing a message > > You mean the NBD server itself, right? Yes, the NBD server should not be printing the redundant error messages that 083.out exposes. > >> (whether the server is python 2 and auto-flushes, >> or python 3 and needs an explicit flush, the message itself is >> pointless, and the test is racy as a result). We may need to revisit >> this patch when that thread is resolved. >> >> https://lists.gnu.org/archive/html/qemu-devel/2018-08/msg01041.html > > Well, it's not like the flush hurts either way. :-) True. On that grounds: Reviewed-by: Eric Blake <eblake@redhat.com> -- Eric Blake, Principal Software Engineer Red Hat, Inc. +1-919-301-3266 Virtualization: qemu.org | libvirt.org