On Fri, Mar 20, 2020 at 20:05:20 +0530, Pankaj Bansal wrote:
> From: Pankaj Bansal <pankaj.bansal@nxp.com>
>
> Add comments to explain the register read and write operation
> on Ds1307. These comments have been referred from data sheet:
>
> https://datasheets.maximintegrated.com/en/ds/DS1307.pdf
>
> Signed-off-by: Pankaj Bansal <pankaj.bansal@nxp.com>
Reviewed-by: Leif Lindholm <leif@nuviainc.com>
> ---
> Silicon/Maxim/Library/Ds1307RtcLib/Ds1307RtcLib.c | 8 ++++++++
> 1 file changed, 8 insertions(+)
>
> diff --git a/Silicon/Maxim/Library/Ds1307RtcLib/Ds1307RtcLib.c b/Silicon/Maxim/Library/Ds1307RtcLib/Ds1307RtcLib.c
> index fd7a8696e405..444e01124811 100644
> --- a/Silicon/Maxim/Library/Ds1307RtcLib/Ds1307RtcLib.c
> +++ b/Silicon/Maxim/Library/Ds1307RtcLib/Ds1307RtcLib.c
> @@ -28,6 +28,11 @@ STATIC EFI_I2C_MASTER_PROTOCOL *mI2cMaster;
>
> /**
> Read RTC register.
> + Data Read-Slave Transmitter Mode
> +
> + <Slave Address> <Word Address (n)> <Slave Address> <Data(n)> <Data(n+1)> <Data(n+2)> <Data(n+X)>
> +
> + The first byte is received and handled as in the slave receiver mode.
>
> @param RtcRegAddr Register offset of RTC to be read.
>
> @@ -69,6 +74,9 @@ RtcRead (
>
> /**
> Write RTC register.
> + Data Write-Slave Receiver Mode
> +
> + <Slave Address> <Word Address (n)> <Data(n)> <Data(n+1)> <Data(n+X)>
>
> @param RtcRegAddr Register offset of RTC to write.
> @param Val Value to be written
> --
> 2.17.1
>
-=-=-=-=-=-=-=-=-=-=-=-