[edk2-devel] [edk2-platforms: PATCH v3 5/9] Marvell/Library: IcuLib: Fix debug information

Marcin Wojtas posted 9 patches 6 years, 4 months ago
There is a newer version of this series
[edk2-devel] [edk2-platforms: PATCH v3 5/9] Marvell/Library: IcuLib: Fix debug information
Posted by Marcin Wojtas 6 years, 4 months ago
In case the number of CP11x components exceeded the maximum
of currently supported, the user is informed with the information.
It turned out that the print arguments were incorrect - fix it.

Signed-off-by: Marcin Wojtas <mw@semihalf.com>
Reviewed-by: Leif Lindholm <leif.lindholm@linaro.org>
---
 Silicon/Marvell/Library/IcuLib/IcuLib.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/Silicon/Marvell/Library/IcuLib/IcuLib.c b/Silicon/Marvell/Library/IcuLib/IcuLib.c
index 343c21b..4d9f174 100644
--- a/Silicon/Marvell/Library/IcuLib/IcuLib.c
+++ b/Silicon/Marvell/Library/IcuLib/IcuLib.c
@@ -280,8 +280,8 @@ ArmadaIcuInitialize (
   if (CpCount > ICU_MAX_SUPPORTED_UNITS) {
     DEBUG ((DEBUG_ERROR,
       "%a: Default ICU to GIC mapping is available for maximum %d CP110 units",
-      ICU_MAX_SUPPORTED_UNITS,
-      __FUNCTION__));
+      __FUNCTION__,
+      ICU_MAX_SUPPORTED_UNITS));
     CpCount = ICU_MAX_SUPPORTED_UNITS;
   }
 
-- 
2.7.4


-=-=-=-=-=-=-=-=-=-=-=-